• Chinese Optics Letters
  • Vol. 14, Issue 2, 023201 (2016)
Xiaoming Lu1、2, Yujie Peng2, Yanyan Li2, Xiaoyang Guo2, Yuxin Leng2、*, Zhan Sui3、**, Yi Xu2, and Xinliang Wang1、2
Author Affiliations
  • 1School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
  • 2State Key Laboratory of High Field Laser Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
  • 3Shanghai Institute of Laser Plasma, Shanghai 201800, China
  • show less
    DOI: 10.3788/COL201614.023201 Cite this Article Set citation alerts
    Xiaoming Lu, Yujie Peng, Yanyan Li, Xiaoyang Guo, Yuxin Leng, Zhan Sui, Yi Xu, Xinliang Wang. High contrast amplification at 1053  nm limited by pulse stretching-compressing process[J]. Chinese Optics Letters, 2016, 14(2): 023201 Copy Citation Text show less
    Output characteristics of the improved pulse cleaning seed: (a) spectrum and (b) third-order correlation contrast measurement.
    Fig. 1. Output characteristics of the improved pulse cleaning seed: (a) spectrum and (b) third-order correlation contrast measurement.
    Schematic of the hybrid double CPA laser system. HWP: half-wave plate; QWP: quarter-wave plate; DM: dichroic mirror; TFP: thin film polarizer; HR: high-reflective mirror.
    Fig. 2. Schematic of the hybrid double CPA laser system. HWP: half-wave plate; QWP: quarter-wave plate; DM: dichroic mirror; TFP: thin film polarizer; HR: high-reflective mirror.
    Spectra of the stretched pulse (black line), the pulse after OPCPA (red line), and the amplified compressed pulse (blue line).
    Fig. 3. Spectra of the stretched pulse (black line), the pulse after OPCPA (red line), and the amplified compressed pulse (blue line).
    Measured autocorrelation trace of the amplified compressed pulse.
    Fig. 4. Measured autocorrelation trace of the amplified compressed pulse.
    Stability of the amplified compressed pulses.
    Fig. 5. Stability of the amplified compressed pulses.
    Third-order correlation contrast measurements of the amplified compressed pulse (black line) and the pulse passed through the stretcher and compressor only (red line).
    Fig. 6. Third-order correlation contrast measurements of the amplified compressed pulse (black line) and the pulse passed through the stretcher and compressor only (red line).
    Xiaoming Lu, Yujie Peng, Yanyan Li, Xiaoyang Guo, Yuxin Leng, Zhan Sui, Yi Xu, Xinliang Wang. High contrast amplification at 1053  nm limited by pulse stretching-compressing process[J]. Chinese Optics Letters, 2016, 14(2): 023201
    Download Citation