• Acta Optica Sinica
  • Vol. 40, Issue 8, 0822002 (2020)
Da Xu1、*, Guoyu Zhang1、2, and Gaofei Sun1、2
Author Affiliations
  • 1School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun, Jilin 130022, China
  • 2Jilin Engineering Research Center of Photoelectric Measurement & Control Instruments, Changchun, Jilin 130022, China;
  • show less
    DOI: 10.3788/AOS202040.0822002 Cite this Article Set citation alerts
    Da Xu, Guoyu Zhang, Gaofei Sun. Design of Advanced Offner-Type Convex Grating Spectral Radiation Calibration Optical System[J]. Acta Optica Sinica, 2020, 40(8): 0822002 Copy Citation Text show less
    Schematic of spectral radiation calibration system
    Fig. 1. Schematic of spectral radiation calibration system
    Schematic of Offner-type imaging system
    Fig. 2. Schematic of Offner-type imaging system
    Meridional light beam imaging
    Fig. 3. Meridional light beam imaging
    Sagittal light beam imaging
    Fig. 4. Sagittal light beam imaging
    Optical structure of advanced Offner-type spectral imaging system
    Fig. 10. Optical structure of advanced Offner-type spectral imaging system
    Spot diagram at λ=500 nm after improvement
    Fig. 11. Spot diagram at λ=500 nm after improvement
    Spot diagram at λ=650 nm after improvement
    Fig. 12. Spot diagram at λ=650 nm after improvement
    Spot diagram at λ=800 nm after improvement
    Fig. 13. Spot diagram at λ=800 nm after improvement
    Curves of RMS radius varies with wavelength after improvement
    Fig. 14. Curves of RMS radius varies with wavelength after improvement
    Smile for advanced Offner-type structure
    Fig. 15. Smile for advanced Offner-type structure
    Color distortion for advanced Offner-type structure
    Fig. 16. Color distortion for advanced Offner-type structure
    SurfaceRadius /mmThickness /mmMaterialLines /(lp·mm-1)
    1-84.50030Mirror
    2-473.67630Grating600
    3-95.06555.545Mirror
    Table 1. Optical structure parameters of traditional Offner-type spectral imaging system
    SurfaceRadius /mmThickness /mmMaterialLines /(lp·mm-1)Tilt angle along X direction /(°)
    1-62.91330Mirror
    2-49.46330.588Grating60010
    3-67.82640.526Mirror
    4-49.3022H-K9L-15.714
    5-64.98825.031
    6Infinity2.997H-K9L
    7Infinity0.480
    Table 2. Optical structure parameters of advanced Offner-type spectral imaging system
    Da Xu, Guoyu Zhang, Gaofei Sun. Design of Advanced Offner-Type Convex Grating Spectral Radiation Calibration Optical System[J]. Acta Optica Sinica, 2020, 40(8): 0822002