    Schematic diagram of measurement system
    Fig. 1. Schematic diagram of measurement system
    1 bit binary pattern
    Fig. 2. 1 bit binary pattern
    Image model of dual line-scan cameras
    Fig. 3. Image model of dual line-scan cameras
    Calibration of line-scan camera. (a) A stereo target with hollow stripes; (b) camera calibration diagram
    Fig. 4. Calibration of line-scan camera. (a) A stereo target with hollow stripes; (b) camera calibration diagram
    Comparative experiment of matching algorithm. (a) On site experimental platform; (b) pictures captured by line-scan camera
    Fig. 5. Comparative experiment of matching algorithm. (a) On site experimental platform; (b) pictures captured by line-scan camera
    Point cloud calculation results of three matching algorithms. (a) Point cloud based on grayscale algorithm; (b) point cloud based on Fourier algorithm; (c) point cloud obtained by Fourier-based gray matching algorithm
    Fig. 6. Point cloud calculation results of three matching algorithms. (a) Point cloud based on grayscale algorithm; (b) point cloud based on Fourier algorithm; (c) point cloud obtained by Fourier-based gray matching algorithm
    Measurement experiment of zirconia standard plate. (a) Physical picture of zirconia plate; (b) image captured by line-scan camera; (c) color difference map of point cloud
    Fig. 7. Measurement experiment of zirconia standard plate. (a) Physical picture of zirconia plate; (b) image captured by line-scan camera; (c) color difference map of point cloud
    ParameterLeft cameraRight camera
    uc /pixel3863.354264.13
    Fx /pixel11087.5311060.43
    r1-3.0623.072
    r20.022-0.020
    r30.6700.696
    Xo /mm428.02-68.63
    Yo /mm21.9825.83
    Zo /mm548.91546.71
    k1 /10-171.820.57
    k2 /10-10-7.56-5.62
    k3 /10-7-4.512.09
    Error /pixel0.230.25
    Table 1. Calibration results of two line-scan cameras
    Linghui Yang, Jincheng Yang, Ruiying Liao, Luyao Ma, Shuotao Hu. Three-Dimensional Measurement Based on Line-Scan Image Fourier and Grayscale Matching Algorithm[J]. Laser & Optoelectronics Progress, 2021, 58(20): 2012001