• Acta Photonica Sinica
  • Vol. 49, Issue 3, 0330002 (2020)
Peng CHEN1, Zhi ZHAO2, Dong-dong ZHAO1、*, Yang-yang HAN2, and Rong-hua LIANG1
Author Affiliations
  • 1College of Computer Science and Technology, Zhejiang University of Technology, Hangzhou 310023, China
  • 2College of Information and Engineering, Zhejiang University of Technology, Hangzhou 310023, China
  • show less
    DOI: 10.3788/gzxb20204903.0330002 Cite this Article
    Peng CHEN, Zhi ZHAO, Dong-dong ZHAO, Yang-yang HAN, Rong-hua LIANG. Detection Method of Dissolved Oxygen Concentration in Water Based on Single Source Frequency Domain Fluorescence Lifetime[J]. Acta Photonica Sinica, 2020, 49(3): 0330002 Copy Citation Text show less
    References

    [1] Q WANG, M Z JIA, L SHUAI. Minreview: recent advances in the development of gaseous and dissolved oxygen sensors. Instrumentation Science & Technology, 47, 19-50(2018).

    [3] A SHRIWASTAV, G SUDARSAN, P BOSE. A modified Winkler's method for determination of dissolved oxygen concentration in water: Dependence of method accuracy on sample volume. Measurement, 106, 190-195(2017).

    [4] GRILLO G J, PEREZ M A, VALLED M, et al. Amplitude phase fluescencespectroscopy methods f dissolved oxygen concentration evaluation: comparative practical results[C]. Canada : IEEE Instrumentation & Measurement Technology Conference, 2005.

    [5] C DEMUTH, J VARONIER, V JOSSEN. Novel probes for pH and dissolved oxygen measurements in cultivations from millilitre to benchtop scale. Applied Microbiology and Biotechnology, 100, 3853-3863(2016).

    [7] W WAN, D HUA, J LE. Study of laser-induced chlorophyll fluorescence lifetime measurement and its correction. Measurement, 60, 64-70(2015).

    [9] Z W XING, W H L. Improvements on the fluorescence quenching-deflection method for real-time in situ simultaneous monitoring of dissolved oxygen and material movement induced beam deflection in the vicinity of an aquatic plant. Analytical Sciences, 34, 1335-1337(2018).

    [10] X F YU, Z DI, X QING. Fabrication of a needle microsensor and its applications in the detection of dissolved oxygen. Journal of Sensors, 408458, 1-7(2015).

    [11] S PENSIERI, R BOZZANO, M SCHIANO. Methods and best practice to intercompare dissolved oxygen sensors and fluorometers/turbidimeters for oceanographic applications. Sensors, 16, 702(2016).

    [12] GUOHUA C, BIN L, et al. Dissolved oxygen detection based on lighttofrequency conversion[C]. 2018 IEEE 3rd Advanced Infmation Technology, Electronic Automation Control Conference (IAEAC), 2018, 13021306.

    [13] M AY, K ÖZGVR. Estimation of dissolved oxygen by using neural networks and neuro fuzzy computing techniques. KSCE Journal of Civil Engineering, 21, 1631-1639(2017).

    [14] D H SONG, H D KIM, K C KIM. Dissolved oxygen concentration field measurement in micro-scale water flows using PtOEP/PS film sensor. Optics and Lasers in Engineering, 50, 74-81(2012).

    [15] MCDOWELL G R, HOLMESSMITH A S, UTTAMLAL M, et al. A robust reliable optical trace oxygen sens[C]. America: International Society f Optics Photonics, 2017: 102310T.

    [16] W FENG, N ZHOU, L X CHEN. An optical sensor for monitoring of dissolved oxygen based on phase detection. Journal of Optics, 15, 5502(2013).

    [17] F M LI, Y G WEI, Y Y CHEN. An intelligent optical dissolved oxygen measurement method based on a fluorescent quenching mechanism. Sensors, 15, 30913-30926(2015).

    [21] C S CHU, Y L LO, T W SUNG. Reviewon recent developments of fluorescent oxygen and carbon dioxide optical fiber sensors. Photonic Sensors, 1, 234-250(2011).

    [22] R WILLIAM. Oxygen quenchig of fluorescence in solution An experimental study of the diffusion process. The Journal of Physical Chemistry, 66, 455-458(1962).

    [23] F M D ROCCA, J NEDBAL, D TYNDALL. Real-time fluorescence lifetime actuation for cell sorting using a CMOS SPAD silicon photomultiplier. Optics Letters, 41, 673-676(2016).

    [25] C WANG, Z LI, Z PAN. Development and characterization of a highly sensitive fluorometric transducer for ultra low aqueous ammonia nitrogen measurements in aquaculture. Computers & Electronics in Agriculture, 150, 364-373(2018).

    Peng CHEN, Zhi ZHAO, Dong-dong ZHAO, Yang-yang HAN, Rong-hua LIANG. Detection Method of Dissolved Oxygen Concentration in Water Based on Single Source Frequency Domain Fluorescence Lifetime[J]. Acta Photonica Sinica, 2020, 49(3): 0330002