    YAO Lu, LIU Wen-qing, LIU Jian-guo*, KAN Rui-feng, XU Zhen-yu, RUAN Jun, YUAN Song. Measurements of CO2 Concentration Profile in Troposphere Based on Balloon-Borne TDLAS System[J]. Spectroscopy and Spectral Analysis, 2015, 35(10): 2787 Copy Citation Text show less

    Abstract

    The main source and sink of CO2 in the atmosphere are concentrated in the troposphere. It is of great significance to the study of CO2 flux and global climate change to obtain the accurate tropospheric CO2 concentration profile. For the characteristics of high resolution, high sensitivity and fast response of tunable diode laser absorption spectroscopy (TDLAS), a compact balloon-borne system based on direct absorption was developed to detect the CO2 concentration profiles by use of the 2 004.02 nm, R(16), ν1+ν3 line without the interfere of H2O absorption and the CO2 density of the number of molecules below 10 km in the troposphere was obtained. Due to the balloon-borne environment, a compact design of one single board integrated with laser driver, signal conditioning, spectra acquiring and concentration retrieving was developed. Limited by the working capability and hardware resources of embedded micro-processor, the spectra processing algorithm was optimized to reduce the time-cost. Compared with the traditional TDLAS sensors with WMS technique, this system was designed based on the direct absorption technique by means of an open-path Herriott cell with 20 m optical-path, which avoided the process of standardization and enhanced the environmental adaptation. The universal design of hardware and software platform achieved diverse gas measuring by changing the laser and adjusting some key parameters in algorithm. The concept of compact design helped to reduce the system’s power and volume and balanced the response speed and measure precision. The power consumes below 1.5 W in room temperature and the volume of the single board is 120 mm×100 mm×25 mm, and the measurement accuracy is ±0.6×10-6 at 1.5 s response time. It has been proved that the system can realize high precision detection of CO2 profile at 15 m vertical resolution in troposphere and TDLAS is an available method for balloon-borne detection.
    YAO Lu, LIU Wen-qing, LIU Jian-guo*, KAN Rui-feng, XU Zhen-yu, RUAN Jun, YUAN Song. Measurements of CO2 Concentration Profile in Troposphere Based on Balloon-Borne TDLAS System[J]. Spectroscopy and Spectral Analysis, 2015, 35(10): 2787
    Download Citation