• Acta Optica Sinica
  • Vol. 30, Issue 2, 579 (2010)
Li Xiang*, Zhang Guangjun, and Li Qingbo
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos20103002.0579 Cite this Article Set citation alerts
    Li Xiang, Zhang Guangjun, Li Qingbo. An Improved Wavelet Analysis Preprocessing Method Applied to Mid-IR Blood Glucose Non-invasive Measurement[J]. Acta Optica Sinica, 2010, 30(2): 579 Copy Citation Text show less
    References

    [1] S. Tomas,C. Richard. Prevention of diabetes with rosiglitazone:Evidence of benefit or unexpected harm[J]. Medical Hypotheses,2008,70(1):199-200

    [2] S. Bruce,J. Thomas,J. S. Linda et al.. Variation in anti-diabetic medication intensity among medicare beneficiaries with diabetes mellitus[J]. The American Journal of Geriatric Pharmacotherapy,2007,5(3):195-208

    [3] Cui Houxin,Xu Kexin,Chen Minsen et al.. Temperature effect on the noninvasive measurement of human blood glucose by NIR[J]. Spectroscopy and Spectral Analysis,2006,126(15):838-841

    [4] Li Qingbo,Xu Kexin,Wang Yan. Primary discussion on prerequisites to noninvasive blood glucose[J]. J. Tianjin University,2003,36(2):139-142

    [5] Li Qingbo,Zhang Lu,Wang Yan et al.. Near-infrared spectroscopic measurement of glucose concentrations in an aqueous matrix-fundamental study on noninvasive measurement method of human blood glucose concentration[J]. Chinese Journal Of Biomedical Engineering,2004,23(6):602-606

    [6] Li Qingbo,Yang Limin,Ling Xiaofeng et al.. Application of the SIMCA method to cancer diagnosis with fourier2[J]. Transform infrared SpectroscopySpectroscopy and Spectral Analysis,2004,24(14):414-417

    [7] Jeongah Yoon,Byungwoo Lee,Chonghun Han. Calibration transfer of near-infrared spectra based on compression of wavelet coefficients[J]. Chemometrics and Intelligent Laboratory Systems,2002,64(1):1-14

    [8] Gang Niu,Achmad Widodo,Jong-Duk Son et al.. Decision-level fusion based on wavelet decomposition for induction motor fault diagnosis using transient current signal[J]. Expert Systems with Applications,2008,35(3):918-928

    [9] Kunpeng Zhu,Yoke Sanwong,Geok Soonhong. Wavelet analysis of sensor signals for tool condition monitoring:A review and some new results[J]. International J. Machine Tools & Manufacture,2009,49:537-553

    [10] Hu-wei Tan,D. B. Steven. Wavelet analysis applied to removing non-constant,varying spectroscopic background in multivariate calibration[J]. J. Chemometrics,2002,16:228-240

    [11] Zhu Hua. The sudy on wavelet analysis and its application to signal de-noising[D]. Wuhan University of Technology,2007. 27-29

    [12] Rainer Martin. Noise power spectral density estimation based on optimal smoothingand minimum statistics[J]. Speech and Audio Processing,IEEE Transactions on,2001,9(5):504-512

    [13] S. Pola,A. Macerata,M. Emdin et al.. Estimation of the power spectral density in nonstationary cardiovascular time series:assessing the role of the time-frequency representations (TFR)[J]. Biomedical Engineering,IEEE Transactions on,1996,43(1):46-59

    [14] S. Poornachandra. Wavelet-based denoising using subband dependent threshold for ECG signals[J]. Digital Signal Processing,2008,18:49-55

    [15] Gülay Tohumoglu,K. Erbil Sezgin. ECG signal compression by multi-iteration EZW coding for different wavelets and thresholds[J]. Computers in Biology and Medicine,2007,37:173-182

    [16] Xu Yizhuang,Zhao Ying,Xu Zhi et al.. Novel infrared spectroscopy methods for clinical diagnosis of tumor[J]. Spectroscopy and Spectral Analysis,2005,25(11):1775-1778

    [17] Payal Roychoudhury,Linda M. Harvey,Brian McNeil. At-line monitoring of ammonium,glucose,methyl oleate and biomass in a complex antibiotic fermentation process using attenuated total reflectance-mid-infrared (ATR-MIR) spectroscopy[J]. Analytica Chimica Acta,2006,561:218-224

    [18] Zhao Ying,Zhang Yuanfu,Yang Limin et al.. A novel non-invasive method of blood glucose measurementusing FT-Mid-IR spectroscopy[J]. Chemical Research in Chinese Universities,2005,26(6):1052-1054

    [19] Sun Ying,Fu Xianbo,Zhou Yong et al.. Study a on noninvasive measurement of blood glucose with FT-IR ATR technique[J]. Chinese J. Minimally Invasive Surgery,2001,1(3):159-161

    CLP Journals

    [1] Ding Haiquan, Lu Qipeng, Chen Xingdan. Effect of Variable Optical Path Length on the Accuracy of the Model in Noninvasive Biochemical Detection by NIR Spectrum[J]. Acta Optica Sinica, 2012, 32(4): 430003

    [2] Li Li, Xie Wenming, Li Hui. Applications of Photoacoustic Spectroscopy in the Field of Modern Biomedicine[J]. Laser & Optoelectronics Progress, 2012, 49(10): 100008

    Li Xiang, Zhang Guangjun, Li Qingbo. An Improved Wavelet Analysis Preprocessing Method Applied to Mid-IR Blood Glucose Non-invasive Measurement[J]. Acta Optica Sinica, 2010, 30(2): 579
    Download Citation