• Acta Photonica Sinica
  • Vol. 43, Issue 10, 1022005 (2014)
WANG Jin-song1、*, NIU Jin2, MA Ying3, WANG Ming4, and HU Mai1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • 4[in Chinese]
  • show less
    DOI: 10.3788/gzxb20144310.1022005 Cite this Article
    WANG Jin-song, NIU Jin, MA Ying, WANG Ming, HU Mai. Wide-field of Infrared Transmissive Collimator System Design[J]. Acta Photonica Sinica, 2014, 43(10): 1022005 Copy Citation Text show less
    References

    [1] KIM S,YANG H,LEE Y.Merit function regression method for efficient alignment control of two-mirror optical systems[J].Optics Express,2007,15(08):5059-5069.

    [2] GUAN Zi-ying,KANG Li-xin,GAO Wei-zhi,et al.Refractive infrared collimator design [C].Second session infrared imaging system simulation,test and evaluation techniques Symposium.2008:586-588.

    [3] KIM E W,KIM Y J.Advanced optical metrology using ultra short pulse lasers,[J].The Review of Laser Engineering,2008,36(Sup):1254-1257.

    [4] MA Jie,ZENG Yu.Based on off-axis catadioptric collimator lens 1.06/1.54μm infrared laser technology Design [J].Infrared Technology,2010,32(2):81-83.

    [5] LI Hong-zhuang,ZHANG Zhen-duo,CAO Jing-tai,et al.High magnification zoom focal length optical system design [J].Acta Photonica Sinica,2012,41(3):358-363.

    [6] HUANG Lei,HU Wen-wen,YANG Zhi-wen.Broad spectrum,long focal length collimating lens optical design [J].Infrared and Laser Engineering,2007,36(S2):1252127.

    [7] MIAO Xing-hua.XUE Ming-qiu.AN Bao-qing.Long focal length collimator.Chinese patent.ZL Patent No.99256104.3.

    [8] CHENG Hui-quan ,YAO Wei-yong,YANG Guo- guang.The imaging of the binary panoramic annular lens based on the combined perspective technique[J].Acta Photonica Sinica,2001,30(9):1111-1114.

    [9] WANG Hu,MIAO Xing-hua,HUI Bing.The distortion correct of short focus wide-angle optical svsteml [J].Acta Photonica Sinica,2001,30(11):1409-1412.

    [10] ZHOU Rui,FANG Jian-cheng,ZHU Shi-ping.Spot size optimization and performance analysis in image measurement[J].Chinese Journal of Scientific Instrument,2000,21(2):177-179

    [11] WU Xiao-ping,ZHOU Qi-bo,WU Man-chang.Large-caliber long focal length collimator system and its installation School optical instrument [J].Optical Instruments,1993,15(5):26-28.

    [12] SHEN Wei-min,XUE Ming-qiu,YU Jian-jun.Relatively large field of large aperture long-wave infrared lens [J].Acta Photonica Sinica,2004,33(4):460-463.

    [13] SHI Jin-feng,WU Qing-wen,YANG Xian-wei.Large-caliber long focal length vertical axis collimator thermal design.[J].Red Outside and Laser Engineering,2013,42(6):1617-1622.

    CLP Journals

    [1] WANG Hong. Optical System Study and Design Used for the Ultraviolet Warning Camera with Ultra-wide Field[J]. Acta Photonica Sinica, 2014, 43(12): 1222004

    WANG Jin-song, NIU Jin, MA Ying, WANG Ming, HU Mai. Wide-field of Infrared Transmissive Collimator System Design[J]. Acta Photonica Sinica, 2014, 43(10): 1022005
    Download Citation