• Acta Optica Sinica
  • Vol. 38, Issue 2, 0222003 (2018)
Danyi Wang, Changxi Xue*, Chuang Li, and Hongfang Yang
Author Affiliations
  • School of Optoelectronic Engineering, Changchun University of Science and Technology, Changchun, Jilin 130022, China
  • show less
    DOI: 10.3788/AOS201838.0222003 Cite this Article Set citation alerts
    Danyi Wang, Changxi Xue, Chuang Li, Hongfang Yang. Design of Electronic Endoscope Optical System Based on Microlens Array[J]. Acta Optica Sinica, 2018, 38(2): 0222003 Copy Citation Text show less
    Coordiantes of microlens array system
    Fig. 1. Coordiantes of microlens array system
    Imaging relationship of a microlens array element
    Fig. 2. Imaging relationship of a microlens array element
    Initial system. (a) Initial layout of electronic endoscope; (b) MTF curves of initial system
    Fig. 3. Initial system. (a) Initial layout of electronic endoscope; (b) MTF curves of initial system
    Optical layout of electronic endoscope. (a) Overall structure; (b) partial enlarged structure
    Fig. 4. Optical layout of electronic endoscope. (a) Overall structure; (b) partial enlarged structure
    Imaging performance of the electronic endoscope optical system. (a) MTF curves; (b) spot diagram; (c) field curvature and distortion
    Fig. 5. Imaging performance of the electronic endoscope optical system. (a) MTF curves; (b) spot diagram; (c) field curvature and distortion
    MTF curves without microlens array
    Fig. 6. MTF curves without microlens array
    ParameterSpecification
    Wavelengths /nm486, 588, 656
    Effective focal length /mm1.55
    F number4.2
    Field of view /(°)110
    MTF /(lp·mm-1)≥30%@120
    Working distance /mm20
    Maximal clear aperture size /mm≤3.2
    Overall length /mm<8
    Table 1. Main design parameters of the electronic endoscope objective system
    AberrationValue /mm
    Spherical aberration1.2×10-3
    Coma7.2×10-4
    Astigmatism3.5×10-3
    Field curvature2.5×10-3
    Axial chromatic aberration-1.9×10-4
    Lateral chromatic aberration-1.8×10-3
    Table 2. Residual aberrations of the electronic endoscope optical system
    Danyi Wang, Changxi Xue, Chuang Li, Hongfang Yang. Design of Electronic Endoscope Optical System Based on Microlens Array[J]. Acta Optica Sinica, 2018, 38(2): 0222003