• Acta Optica Sinica
  • Vol. 39, Issue 5, 0512006 (2019)
Yan Wang, Lu Fu, Ping Chen*, Xiyun Liu, Weiwei Liu, and Lie Lin
Author Affiliations
  • Institute of Modern Optics, College of Electronic Information and Optical Engineering, Nankai University, Tianjin 300350, China
  • show less
    DOI: 10.3788/AOS201939.0512006 Cite this Article Set citation alerts
    Yan Wang, Lu Fu, Ping Chen, Xiyun Liu, Weiwei Liu, Lie Lin. Design of Schmidt Corrector Plate for Cancelling Aberrations of Spectrometers[J]. Acta Optica Sinica, 2019, 39(5): 0512006 Copy Citation Text show less
    Schematics of aberration. (a) Spherical reflector; (b) compensation using Schmidt corrector plate
    Fig. 1. Schematics of aberration. (a) Spherical reflector; (b) compensation using Schmidt corrector plate
    Diagram of Schimtt system
    Fig. 2. Diagram of Schimtt system
    Schematic of Schmidt corrector plate with zero defocus
    Fig. 3. Schematic of Schmidt corrector plate with zero defocus
    Schematic of Schmidt system with off-axis parallel light
    Fig. 4. Schematic of Schmidt system with off-axis parallel light
    Design diagram and surface shape of Schmidt corrector plate in spectrometer. (a) Design diagram; (b) surface shape
    Fig. 5. Design diagram and surface shape of Schmidt corrector plate in spectrometer. (a) Design diagram; (b) surface shape
    Optical design of aberration cancellation spectrometer based on Schmidt corrector plate
    Fig. 6. Optical design of aberration cancellation spectrometer based on Schmidt corrector plate
    Parameter settings of original spectrometer and bitmaps of light spots on image plane at different wavelengths. (a) Optical path in spectrometer; (b) bitmap at 350 nm; (c) bitmap at 550 nm; (d) bitmap at 700 nm
    Fig. 7. Parameter settings of original spectrometer and bitmaps of light spots on image plane at different wavelengths. (a) Optical path in spectrometer; (b) bitmap at 350 nm; (c) bitmap at 550 nm; (d) bitmap at 700 nm
    Parameter settings of spectrometer with calibration plate and bitmaps of light spots on image plane at different wavelengths. (a) Results of ray tracing of spectrometer by ZEMAX based on Schmidt corrector plate; (b) bitmap at 350 nm; (c) bitmap at 550 nm; (d) bitmap at 700 nm
    Fig. 8. Parameter settings of spectrometer with calibration plate and bitmaps of light spots on image plane at different wavelengths. (a) Results of ray tracing of spectrometer by ZEMAX based on Schmidt corrector plate; (b) bitmap at 350 nm; (c) bitmap at 550 nm; (d) bitmap at 700 nm
    Yan Wang, Lu Fu, Ping Chen, Xiyun Liu, Weiwei Liu, Lie Lin. Design of Schmidt Corrector Plate for Cancelling Aberrations of Spectrometers[J]. Acta Optica Sinica, 2019, 39(5): 0512006
    Download Citation