• Laser & Optoelectronics Progress
  • Vol. 60, Issue 23, 2304001 (2023)
Haisheng Song1, Rongni Pang1、2、*, and Xiao Cai2
Author Affiliations
  • 1School of Physics and Electronic Engineering, Northwest Normal University, Lanzhou 730070, Gansu, China
  • 2State Key Laboratory of Nuclear Detectors and Nuclear Electronics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100043, China
  • show less
    DOI: 10.3788/LOP223019 Cite this Article Set citation alerts
    Haisheng Song, Rongni Pang, Xiao Cai. Effect of Germanium Dead Layer on Detection Efficiency of High-Purity Germanium Based on Monte Carlo Simulations[J]. Laser & Optoelectronics Progress, 2023, 60(23): 2304001 Copy Citation Text show less
    References

    [1] Deng H J, Lai W C, Gan L et al. The efficiency calibration methods in measuring environmental samples by HPGe gamma spectrometer[J]. Nuclear Electronics & Detection Technology, 34, 1283-1286(2014).

    [2] Zhang B Q, Ma J Z, Cheng J P et al. Calculation of the detection efficiency of an HPGe detector in low energy photon measurement with Monte Carlo method[J]. Nuclear Electronics & Detection Technology, 25, 274-277(2005).

    [3] Jiang H, Yue Q, Li Y L et al. Measurement of the dead layer thickness in a p-type point contact germanium detector[J]. Chinese Physics C, 82-88(2016).

    [4] Ródenas J et al. Analysis of the influence of germanium dead layer on detector calibration simulation for environmental radioactive samples using the Monte Carlo method[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 496, 390-399(2003).

    [5] Budjáš D et al. Optimisation of the MC-model of a p-type Ge-spectrometer for the purpose of efficiency determination[J]. Applied Radiation and Isotopes, 67, 706-710(2009).

    [6] Vargas M J, Timón A F, Sánchez D et al. Monte Carlo simulation of the self-absorption corrections for natural samples in gamma-ray spectrometry[J]. Applied Radiation and Isotopes, 57, 893-898(2002).

    [7] Hardy J C et al. Precise efficiency calibration of an HPGe detector: source measurements and Monte Carlo calculations with sub-percent precision[J]. Applied Radiation and Isotopes, 56, 65-69(2002).

    [8] Han L W, Gao Y D, Xia X H et al. Passive efficiency calibration of HPGe detector based on MCNP[J]. Nuclear Safety, 19, 76-80(2020).

    [9] Khan W, Zhang Q, He C et al. Monte Carlo simulation of the full energy peak efficiency of an HPGe detector[J]. Applied Radiation and Isotopes, 131, 67-70(2018).

    [10] Lam C H, Ling C C. Decomposition of positron lifetime spectra generated by Monte Carlo method: The case study of 6H silicon carbide[J]. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 251, 479-483(2006).

    [11] Agostinelli S, Allison J, Amako Ket. Geant4: a simulation toolkit[J]. Nuclear Instruments and Methods in Physics Research, 506, 250-303(2003).

    [12] Ródenas J, Martinavarro A, Rius V. Validation of the MCNP code for the simulation of Ge-detector calibration[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 450, 88-97(2000).

    [13] Huy N Q. The influence of dead layer thickness increase on efficiency decrease for a coaxial HPGe p-type detector[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 621, 390-394(2010).

    [14] Azbouche A, Belamri M, Tchakoua T. Study of the germanium dead layer influence on HP(Ge) detector efficiency by Monte Carlo simulation[J]. Radiation Detection Technology and Methods, 2, 45(2018).

    Haisheng Song, Rongni Pang, Xiao Cai. Effect of Germanium Dead Layer on Detection Efficiency of High-Purity Germanium Based on Monte Carlo Simulations[J]. Laser & Optoelectronics Progress, 2023, 60(23): 2304001