• Acta Optica Sinica
  • Vol. 34, Issue 8, 804001 (2014)
Ni Qiliang*
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos201434.0804001 Cite this Article Set citation alerts
    Ni Qiliang. Optimization for Spatial Resolution and Count Rate of a Far Ultraviolet Photon-Counting Imaging Detector Based on Induced Charge Position-Sensitive Anode[J]. Acta Optica Sinica, 2014, 34(8): 804001 Copy Citation Text show less
    References

    [1] R P McCoy. Space weather comes of age-new sensors and models for ionospheric specification and forecast [C]. SPIE, 2004, 5548: 341-347.

    [2] K F McCoy, G G Dymond, S E Fritz, et al.. Special sensor ultraviolet limb imager: an ionospheric and neutral density profiler for the defense meteorological satellite program satellites [J]. Opt Eng, 1994, 33(2): 423-429.

    [3] D C Humm, L J Paxton, A B Christensen. Design and performance of the global ultraviolet imager (GUVI) [J]. SPIE, 1998, 3445: 2-12.

    [4] S E Thonnard, S A Budzien, A C Nicholas. An update on the calibration and performance of the special sensor ultraviolet limb imagers (SSULI) [C]. SPIE, 1999, 3818: 90-98.

    [5] J S Lapington. A comparison of readout techniques for high-resolution imaging with microchannel plate detectors [J]. Nuclear Instruments and Methods in Physics Research A, 2004, 525(1-2): 361-365.

    [6] C Martin, P Jelinsky, M Lampton, et al.. Wedge-and-strip anodes for centroid-finding position-sensitive photon and particle detectors [J]. Rev Sci Instrum, 1981, 52(7): 1067-1074.

    [7] Yu Lei, Qu Yi, Lin Guanyu, et al.. Design and study of an optical system for a far ultraviolet imaging spectrograph in 120~180 nm carried by satellite [J]. Acta Optica Sinica, 2011, 31(1): 0112011.

    [8] Yu Lei, Wang Shurong, Qu Yi, et al.. Single-grating of optical system of imaging spectrometer with high resolution for ionosphere detection [J]. Acta Optica Sinica, 2011, 31(7): 0712005.

    [9] Xue Qingsheng, Wang Shurong, Li Futian. Study on limb imaging spectrometer with grating dispersion [J]. Acta Optica Sinica, 2010, 30(5): 1514-1521.

    [10] Zhang Zhenduo, Wang Shurong, Li Futian, et al.. Study on calibration method of spectral irradiance responsivity for space ultraviolet remote sensing instrument [J]. Acta Optica Sinica, 2010, 30(6): 1816-1821.

    [11] O H W Siegmund, M Lampton, S Chakrabarti, et al.. Application of wedge and stripe image readout systems to detectors for astronomy [C]. SPIE, 1986, 627: 660-665.

    [12] J S Lapingtona, H E Schwarz. The design and manufacture of wedge and strip anode [J]. IEEE Trans Nucl Sci, 1986, 33(1): 288-292.

    [13] V Radeka. Low noise techniques in detectors [J]. Ann Rev Nucl Part Sci, 1988, 38(38): 217-277.

    [14] F S Goulding, D A Landis. Signal processing for semiconductor detectors [J]. IEEE Trans Nucl Sci, 1982, NS29(3): 1125-1141.

    CLP Journals

    [1] XING Yan, CHEN Bo, JIN Fang-yuan, WANG Hai-feng, ZHANG Hong-ji, HE Ling-ping. The Partition Noise Research of MCP Photon Counting Imager Detector Based on Vernier Anode[J]. Acta Photonica Sinica, 2016, 45(6): 604002

    [2] Zhao Dachun, Chen Bo, Liu Peng, Zhang Hongji. Theoretical Prediction of Flat Circular-Channel MCP Performance for Focusing X-Rays[J]. Acta Optica Sinica, 2015, 35(9): 934002

    Ni Qiliang. Optimization for Spatial Resolution and Count Rate of a Far Ultraviolet Photon-Counting Imaging Detector Based on Induced Charge Position-Sensitive Anode[J]. Acta Optica Sinica, 2014, 34(8): 804001
    Download Citation