• Infrared and Laser Engineering
  • Vol. 47, Issue 4, 404002 (2018)
Xie Chenyu1、2、*, Li Jianjun1, Pang Weiwei1, Xia Maopeng1, and Zheng Xiaobing1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/irla201847.0404002 Cite this Article
    Xie Chenyu, Li Jianjun, Pang Weiwei, Xia Maopeng, Zheng Xiaobing. Reseach on calibration method of double-channel thermal-infrared standard radiometer[J]. Infrared and Laser Engineering, 2018, 47(4): 404002 Copy Citation Text show less
    References

    [1] Xu Jun, Meng Binghuan, Zheng Xiaobing, et al. Calibration of common temperature blackbody based on thermal-infrared standard radiometer[J]. Infrared and Laser Engineering, 2013, 43(3): 716-721. (in Chinese)

    [2] Chen Muwang, Qi Hongxing, Gong Yumei, et al. Analysis of effect of calibration blackbody temperature stability on the infrared imaging[J]. Infrared and Laser Engineering, 2006, 35(6): 652-654. (in Chinese)

    [3] Rice J P, Johnson B C. The NIST EOS thermal infrared transfer radiometer[J]. Metrologia, 2010, 35: 505-509.

    [4] Rice J P, Bender S C, Atkins W H, et al. Deployment test of the NIST EOS thermal-infrared transfer radiometer[J]. International Journal of Remote Sensing, 2003, 24(2): 367-388.

    [5] Adriaan C C, Raju U D, Timothy M J, et al. Low-background temperature calibration of infrared blackbodies [J]. Metrologia, 2006, 43: 46-50.

    [6] Yue Wenlong. Research of the calibration technology for blackbody radiation source[D]. Xi′an: Xi′an Technological University, 2007. (in Chinese)

    [7] Zhu Qihai, Li Xiansheng, Ren Jianwei, et al. Development and calibration of infrared double-channel spectral radiometer[J]. Optical Technique, 2006, 32(5): 773-778. (in Chinese)

    [8] Zhang Lei, Zheng Xiaobing, Zhang Liming, et al. High accuracy water bath blackbody based on the information quantification of infrared remote sensing[J]. Optical Technique, 2007, 33(2): 245-251. (in Chinese)

    [9] Zhang Lei. Study on the spectral radiometric calibration technique of infrared stand transfer detector[D]. Hefei: Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, 2007. (in Chinese)

    [10] Fang Qianqian, Fang Wei, Wang Kai, et al. Calculation of effective of blackbody cavities by Monte-Carlo method [J] Chinese Optics, 2012, 5(2): 167-173. (in Chinese)

    [11] Xun Jun. Research on calibration of ambient temperature blackbodies based on a thermal-infrared standard Radiometer [D]. Hefei: Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, 2013. (in Chinese)

    Xie Chenyu, Li Jianjun, Pang Weiwei, Xia Maopeng, Zheng Xiaobing. Reseach on calibration method of double-channel thermal-infrared standard radiometer[J]. Infrared and Laser Engineering, 2018, 47(4): 404002
    Download Citation