A novel non-contact fiber optic accelerometer is presented. The velocity of a moving target is sampled at different times by two beams originating from the same laser but with different feed path lengths. The acceleration of the target is measured by heterodyning the two Doppler shifted return beams. By directing each return beam to the detector via the feed path taken by the other beam, equal path lengths are ensured relaxing the coherency requirements of the light source.