[1] M Lombardo, S Serrao, N Devaney, et al.. Adaptive optics technology for high-resolution retinal imaging [J]. Sensors (Basel), 2013, 13(1): 334-366.
[2] Michael Bass, Jay M Enoch. Handbook of Optics Volume Ⅲ: Vision and Vsion Optics [M]. McGraw-Hill, 2010.
[3] Wang Yuliang, Li Kai. Ophthalmology & Opthometry [M]. Beijing: People′s Military Medical Press, 2008.
[4] Antonio Guirao, Jason Porter, David R Williams, et al.. Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes: erratum [J]. J Opt Soc Am A, 2002, 19(3): 620-628.
[5] W N Charman, N Chateau. The prospects for super-acuity: limits to visual performance after correction of monochromatic ocular aberration [J]. Ophthalmic and Physiological Optics, 2003, 23(6): 479-493.
[6] Larry N Thibos, Xin Hong, Arthur Bradley, et al.. Statistical variation of aberration structure and image quality in a normal population of healthy eyes [J]. J Opt Soc Am A, 2002, 19(12): 2329-2348.
[7] Jungtae Rha, Ravi S Jonnal, Karen E Thorn, et al.. Adaptive optics flood-illumination camera for high speed retinal imaging [J]. Opt Express, 2006, 14(10): 4552-4569.
[8] Yan Zhang, Jungtae Rha, Ravi Jonnal, et al.. Adaptive optics parallel spectral domain optical coherence tomography for imaging the living retina [J]. Opt Express, 2005, 13(12): 4792-4811.
[9] Austin Roorda, Fernando Romero-Borja, William Donnelly III, et al.. Adaptive optics scanning laser ophthalmoscopy [J]. Opt Express, 2002, 10(9): 405-412.
[10] Zhou Hong, Guan Chunlin, Dai Yun. Bimorph deformable mirrors for adaptive optics of human retinal imaging system [J]. Acta Optica Sinica, 2013, 33(2): 0211001.
[11] Tan Zuojun, Xie Jing, Lu Jun, et al.. High spatial resolution confocal microscopy using adaptive optics [J]. Laser & Optoelectronics Progress, 2012, 49(9): 090002.
[12] Kong Ningning, Li Dayu, Xia Mingliang, et al.. Liquid crystal adaptive optics system for retinal imaging operated on open-loop and double-palse mode [J]. Acta Optica Sinica, 2012, 32(1): 0111002.
[13] Y He, H Li, J Lu, et al.. Retina imaging by using compact line scanning quasi-confocal ophthalmoscope [J]. Chin Opt Lett, 2013, 11(2): 021101.
[15] G Liu, R Wang. Stripe motion artifact suppression in phase-resolved OCT blood flow image of the human eye based on the frequency rejection filter [J]. Chin Opt Lett, 2013, 11(3): 031701.
[16] Junzhong Liang, David R Williams, Donald T Miller. Supernormal vision and high-resolution retinal imaging through adaptive optics [J]. J Opt Soc Am A, 1997, 14(11): 2884-2892.
[17] Enrique J Fernández, Ignacio Iglesias, Pablo Artal. Closed-loop adaptive optics in the human eye [J]. Opt Lett, 2001, 26(10): 746-748.
[18] M Glanc, E Gendron, F Lacombe, et al.. Towards wide-field retinal imaging with adaptive optics [J]. Opt Commun, 2004, 230(4): 225-238.
[20] Qi Yue. Retinal Microvasculature Imaging Research Based-on the Liquid Crystal Adaptive Optics [D]. Beijing: University of Chinese Academy of Sciences, 2013.
[21] F Delplancke. Automated high-speed Mueller matrix scatterometer [J]. Appl Opt, 1997, 36(22): 5388-5395.
[22] Andreas Hielscher, Angela Eick, Judith Mourant, et al.. Diffuse backscattering Mueller matrices of highly scattering media [J]. Opt Express, 1997, 1(13): 441-453.
[23] Brent D Cameron, M J Rakovic, Mehrübe Mehrübeoglu, et al.. Measurement and calculation of the two-dimensional backscattering Mueller matrix of a turbid medium [J]. Opt Lett, 1998, 23(7): 485-487.
[24] William S Bickel, Wilbur M Bailey. Stokes vectors, Mueller matrices, and polarized scattered light [J]. American Journal of Physics, 1985, 53(5): 468-478.
[25] Chao Li, Dayu Li, Quanquan Mu, et al.. High-resolution retinal imaging through open-loop adaptive optics [J]. Journal of Biomedical Optics, 2010, 15(4): 046009.
[26] Jason Porter, Hope Queener, Julianna Lin, et al.. Adaptive Optics for Vision Science: Principles, Practices, Design and Applications [M]. New York: John Wiley & Sons, 2006. 55-56.
[27] Van Den Berg, Thomas J T P O D, F A A O. Analysis of intraocular straylight, especially in relation to age [J]. Optometry & Vision Science, 1995, 72(2): 52-59.
[28] T J T P Van den Berg, J K I J speert, P W T de Waard. Dependence of intraocular straylight on pigmentation and light transmission through the ocular wall [J]. Vision Research, 1991, 31(7): 1361-1367.
[29] J J Vos, J Boogaard. Contribution of the cornea to entoptic scatter [J]. J Opt Soc Am, 1963, 53(7): 869-873.
[30] Robert M Boynton, Frank J J Clarke. Sources of entoptic scatter in the human eye [J]. J Opt Soc Am, 1964, 54(1): 110-119.
[31] J J Vos. Contribution of the fundus oculi to entoptic scatter [J]. J Opt Soc Am, 1963, 53(12): 1449-1451.
[32] Richard P Hemenger. Small-angle intraocular light scatter: a hypothesis concerning its source [J]. J Opt Soc Am A, 1988, 5(4): 577-582.
[33] Walter Stanley Stiles. The effect of glare on the brightness difference threshold [J]. Proceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character, 1929: 322-351.
[34] L L Holladay. The fundamentals of glare and visibility [J]. J Opt Soc Am, 1926, 12(4): 271-319.
[35] Juan M Bueno, Esther Berrio, Maris Ozolinsh, et al.. Degree of polarization as an objective method of estimating scattering [J]. J Opt Soc Am A, 2004, 21(7): 1316-1321.
[36] Pablo Artal, Ignacio Iglesias, Norberto Lopez-Gil, et al.. Double-pass measurements of the retinal-image quality with unequal entrance and exit pupil sizes and the reversibility of the eye′s optical system [J]. J Opt Soc Am A, 1995, 12(10): 2358-2366.
[37] Justin M Wanek, Marek Mori, Mahnaz Shahidi. Effect of aberrations and scatter on image resolution assessed by adaptive optics retinal section imaging [J]. J Opt Soc Am A, 2007, 24(5): 1296-1304.
[38] Gerald Westheimer, Junzhong Liang. Influence of ocular light scatter on the eye′s optical performance [J]. J Opt Soc Am A, 1995, 12(7): 1417-1424.
[39] Fernando Díaz-Doutón, Antonio Benito, Jaume Pujol, et al.. Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument [J]. Investigative Ophthalmology & Visual Science, 2006, 47(4): 1710-1716.
[41] Pablo Artal, Susana Marcos, Rafael Navarro, et al.. Odd aberrations and double-pass measurements of retinal image quality [J]. J Opt Soc Am A, 1995, 12(2): 195-201.
[42] F W Campbell, R W Gubisch. Optical quality of the human eye [J]. The Journal of Physiology, 1966, 186(3): 558-578.
[43] R A Weale. Polarized light and the human fundus oculi [J]. The Journal of Physiology, 1966, 186(1): 175.
[44] M Millodot. Reflection from the fundus of the eye and its relevance to retinoscopy [J]. Atti Fond Giorgio Ronchi, 1972, 27: 31-50.
[45] Max Born, Emil Wolf. Principles of optics: electromagnetic theory of propagation, interference and diffraction of light [M]. Cambridge: Cambridge University Press, 1999.
[46] World Medical Association. Declaration of Helsinki. Ethical principles for medical research involving human subjects[J]. http://www.wma. net/e/policy/b3. htm, 2008.