• Acta Optica Sinica
  • Vol. 35, Issue 11, 1134002 (2015)
Wang Xuepeng*, Yang Jing, Wang Lili, Li Yude, Guo Fei, Zhao Weilin, Fu Site, and Lin Xiaoyan
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos201535.1134002 Cite this Article Set citation alerts
    Wang Xuepeng, Yang Jing, Wang Lili, Li Yude, Guo Fei, Zhao Weilin, Fu Site, Lin Xiaoyan. Measurement of Line Absorption Coefficient of Cylindrical Tungsten/Glass Complex Optical Component[J]. Acta Optica Sinica, 2015, 35(11): 1134002 Copy Citation Text show less
    References

    [1] Chen Xiangcun, Li Ruipeng, Liu Ke, et al.. Study on single-bounced capillary focus based on NSRLX-ray diffraction and scattering station[J]. Nuclear Electronics & Detection Technology, 2010, 30(9): 1150-1155.

    [2] K Ricketts, C Guazzoni, A Castodi, et al.. An X- ray fluorescence imaging system for gold nanoparticledetection[J]. Physics in Medicine and Biology, 2013, 58(21): 7841-7855.

    [3] M Dehlinger, C Fauquet, F Jandaed, et al.. Toward sub-micro-XRF working at nanometer range using capillary optics[J]. X-Ray Spectrometry, 2013, 42(6): 456-461.

    [4] B Ravel, K Attenkofer, J Bohon, et al.. Diamond sensors and polycapillary lenses for X-ray absorption spectroscopy[J]. Review of Scientific Instruments, 2013, 84(10): 103106.

    [5] Xingchen Pan, S P Veetil, Cheng Liu, et al.. High-contrast imaging for weakly diffracting specimens in coherent diffracting imaging [J]. Chin Opt Lett, 2013, 11(2): 021103.

    [6] A Bjeoumikhova, M Erko, S Bjeoumikhova, et al.. Capillary μFocus X-ray lenses with parabolic and elliptic profile[J]. Nuclear Instruments and Methods in Physics Research A, 2008, 587(2): 458-463.

    [7] Sun Tianxi, Liu Zhiguo, Peng Song, et al.. Study on resolution limit of total-reflection X-ray optics with Heisenberg uncertainty principle[J]. Chinese J Lasers, 2013, 40(12): 1217001.

    [8] Zhi Chen, Hongan Xie, Biao Geng, et al.. Toward one nanometer X-ray focusing: a complex refractive lens design[J]. Chin Opt Lett, 2014, 12(12): 123401.

    [9] R Mroczka, G Zukocinski, A Kuczumow. Investigations of X-ray metallic capillaries[J]. Journal of Alloys and Compounds, 2005, 401(1): 108-117.

    [10] R Mrouka, P Bartosik, Z Sawlowicz, et al.. Optimization of metallic X-ray capillary production[J]. Thin Solid Films, 2008, 516(22): 8029-8035.

    [11] Li Yude, Lin Xiaoyan, Wang Dachun. Study on the convergent function of a cylinder capillary transmitting X-ray[J]. High Energy Physics and Nuclear Physics, 2006, 30(9): 916-919.

    [12] National Institute of Standards and Technology. NIST Atomic Spectra Database Lines Form[OL]. http://physics.nist.gov/PhysRefData/ASD/lines_form.html[2015-07-01].

    Wang Xuepeng, Yang Jing, Wang Lili, Li Yude, Guo Fei, Zhao Weilin, Fu Site, Lin Xiaoyan. Measurement of Line Absorption Coefficient of Cylindrical Tungsten/Glass Complex Optical Component[J]. Acta Optica Sinica, 2015, 35(11): 1134002
    Download Citation