• Chinese Optics Letters
  • Vol. 1, Issue 6, 06326 (2003)
Dongqing Zhang1、2、*, Fuquan Wu1, and Shuhai Fan1、2
Author Affiliations
  • 1Laser Research Institute of Qufu Normal University, Qufu 273165
  • 2Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800
  • show less
    DOI: Cite this Article Set citation alerts
    Dongqing Zhang, Fuquan Wu, Shuhai Fan. The optimum scheme of a static Fourier-transform spectrometer based on birefringent crystal[J]. Chinese Optics Letters, 2003, 1(6): 06326 Copy Citation Text show less

    Abstract

    An optimum design of static Fourier-transform spectrometer based on Savert prisms is presented in this paper. A new method of increasing path difference and resolution of spectrometer is given. When the angle between the crystal optical axis of the first Savert prism and the incident interface is 58°and the angle between the crystal optical axis of the second Savert prism and the incident interface is 28°, the maximum path difference will be 0.63 mm, the maximum resolution will be 15.8 cm^(-1), and the whole field-of-view will reach 6°.
    Dongqing Zhang, Fuquan Wu, Shuhai Fan. The optimum scheme of a static Fourier-transform spectrometer based on birefringent crystal[J]. Chinese Optics Letters, 2003, 1(6): 06326
    Download Citation