• Chinese Journal of Lasers
  • Vol. 47, Issue 6, 604006 (2020)
Du Xinghu1、2、3, Xue Ying1、2、3, He Xing1、2, Wang Shuai1、2, Yang Ping1、2, and Xu Bing1、2
Author Affiliations
  • 1Key Laboratory of Adaptive Optics, Chinese Academy of Sciences, Chengdu, Sichuan 610209, China
  • 2Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, Sichuan 610209, China
  • 3University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.3788/CJL202047.0604006 Cite this Article Set citation alerts
    Du Xinghu, Xue Ying, He Xing, Wang Shuai, Yang Ping, Xu Bing. High Reflectivity Measurement Based on Coupled Cavity Ring-Down Technique[J]. Chinese Journal of Lasers, 2020, 47(6): 604006 Copy Citation Text show less
    References

    [1] Sanders V. High-precision reflectivity measurement technique for low-loss laser mirrors[J]. Applied Optics, 16, 19-20(1977).

    [2] Anderson D Z, Frisch J C, Masser C S. Mirror reflectometer based on optical cavity decay time[J]. Applied Optics, 23, 1238-1245(1984).

    [3] O'Keefe A. Deacon D A G. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources[J]. Review of Scientific Instruments, 59, 2544-2551(1988).

    [4] von Lerber T, Sigrist M W. Cavity-ring-down principle for fiber-optic resonators: experimental realization of bending loss and evanescent-field sensing[J]. Applied Optics, 41, 3567(2002).

    [5] Li B C, Gong Y. Review of cavity ring-down techniques for high reflectivity measurements[J]. Laser & Optoelectronics Progress, 47, 021203(2010).

    [6] Westberg J, Wysocki G. Cavity ring-down Faraday rotation spectroscopy for oxygen detection[J]. Applied Physics B, 123, 168(2017).

    [7] Cui H, Li B C, Xiao S L et al. Simultaneous measurement of S- and P-polarization reflectivity using optical feedback cavity ring down technique[J]. Journal of University of Electronic Science and Technology of China, 47, 307-310(2018).

    [8] Kastler A. Transmission of light pulse through a Fabry-Perot interferometer[J]. Nouvelle Revue d'Optique, 5, 133-139(1974).

    [9] Sun F G, Dai D X, Xie J C et al. Accurate reflectivity measurement of high reflective mirrors via a cavity ring-down method[J]. Chinese Journal of Lasers, 26, 35-38(1999).

    [10] Li L P, Liu T, Li G et al. Measurement of ultra-low losses in optical supercavity[J]. Acta Physica Sinica, 53, 1401-1405(2004).

    [11] Pipino A C R, Hudgens J W, Huie R E. Evanescent wave cavity ring-down spectroscopy with a total-internal-reflection minicavity[J]. Review of Scientific Instruments, 68, 2978-2989(1997).

    [12] Stewart G. Intra-cavity and ring-down cavity absorption with fibre amplifiers for trace gas detection[J]. Proceedings of SPIE, 4185, 41852F(2000).

    [13] Courtois J, Hodges J T. Coupled-cavity ring-down spectroscopy technique[J]. Optics Letters, 37, 3354-3356(2012).

    [14] Tan Z Q, Long X W. Influence of mode mismatch on measurement of continuous-wave cavity ring-down technology[J]. Chinese Journal of Lasers, 34, 962-966(2007).

    [15] He X. Study on precise and accurate measurement technique of high reflectivity Chengdu: Institute of Optics and Electronics,[D]. Chinese Academy of Sciences(2016).

    [16] Wang J D, Yu J, Mo Z Q et al. Numerical methods of mode selection in continuous-wave cavity ring-down spectroscopy[J]. Acta Physica Sinica, 68, 159-169(2019).

    Du Xinghu, Xue Ying, He Xing, Wang Shuai, Yang Ping, Xu Bing. High Reflectivity Measurement Based on Coupled Cavity Ring-Down Technique[J]. Chinese Journal of Lasers, 2020, 47(6): 604006
    Download Citation