• Opto-Electronic Engineering
  • Vol. 35, Issue 1, 71 (2008)
FU Dan*, FENG Wei-dong, YU Qi-fen, and XU Yi-dan
Author Affiliations
  • [in Chinese]
  • show less
    DOI: Cite this Article
    FU Dan, FENG Wei-dong, YU Qi-fen, XU Yi-dan. Linear Self-calibration Method for Camera[J]. Opto-Electronic Engineering, 2008, 35(1): 71 Copy Citation Text show less
    References

    [1] Tsai Y R.A Versatile Camera Calibration Technique for High-accuracy 3D Machine Vision Metrology Using offthe Shelf TV Cameras and Lenses[J].IEEE Journal of Robotics and Automation,1987,3(4):323-344

    [2] SHANG Yang,YU Qi-feng,ZHANG Xiao-hu.Analytical Method for Camera Calibration from a Single Image with Four Coplanar Control Lines[J].Applied Optics,2004,43(28):5364-5369

    [3] Caprile B,Torre V.Using Vanishing Points for Camera Calibration[J].International Journal of Computer Vision,1990,4(2):127-140

    [4] Hartley R,Zisserman A.Multiple View Geometry in Computer Vision[M].Cambridge,UK:Cambridge University Press,2000

    [5] Kanatani K.Statistical A alysis of Focul-length Calibration Using Vanishing Points[J].IEEE Trans.on RA,1992,8(6):767-775

    [6] Jelinek D,Taylor C J.Reconstruction of linearly parameterized models from single images with a camera of unknown focal length[J].IEEE Trans.on PAMI,2001,23(7):767-774

    CLP Journals

    [1] ZHANG De-hai, LIANG Jin, TANG Zheng-zong, GUO Cheng, CAO Ju-ming, WANG Huan. Exploitation and Study of Close Range Industry Photogrammetry System Based on Large-scale Complex Surface Products[J]. Opto-Electronic Engineering, 2009, 36(5): 122

    [2] ZHOU Xiao, SHEN Jian-xin, LIAO Wen-he, YE Yong-qiang. Iris Recognition Based on Regional Grayscale Change[J]. Opto-Electronic Engineering, 2010, 37(10): 104

    [3] QI Zhan-hui, ZHANG Suo-ping. Non-calibration Points Algorithm for the Image Correction[J]. Opto-Electronic Engineering, 2009, 36(1): 31

    [4] YUAN Wei-qi, CHEN Lei, CHANG Le. Iris Matching Method Based on Segmentation Shifting[J]. Opto-Electronic Engineering, 2010, 37(3): 110

    [5] YE Yong-qiang, SHEN Jian-xin, ZHOU Xiao. Rapid Iris Location Method Based on Grayscale Features of Pupil Areas[J]. Opto-Electronic Engineering, 2010, 37(3): 127

    [6] QI Chuan-qi, BAO Hua, YANG Han-sheng, DAI Yun. Identification Recognition Based on High Resolution Retinal Capillary Vessel Image of Human Eye[J]. Opto-Electronic Engineering, 2009, 36(9): 132

    FU Dan, FENG Wei-dong, YU Qi-fen, XU Yi-dan. Linear Self-calibration Method for Camera[J]. Opto-Electronic Engineering, 2008, 35(1): 71
    Download Citation