• Spectroscopy and Spectral Analysis
  • Vol. 41, Issue 2, 499 (2021)
Yan-jie CHEN1、1、*, Yu-qian CUI1、1, Qing-song LI1、1, Bo-qiang LI1、1, Ji-ping WANG1、1, Guo-yuan CHEN1、1, Jie LIAO1、1, and Guo-xin LI1、1
Author Affiliations
  • 1[in Chinese]
  • 11. School of Environmental Science and Engineering, Qingdao University, Qingdao 266071, China
  • show less
    DOI: 10.3964/j.issn.1000-0593(2021)02-0499-06 Cite this Article
    Yan-jie CHEN, Yu-qian CUI, Qing-song LI, Bo-qiang LI, Ji-ping WANG, Guo-yuan CHEN, Jie LIAO, Guo-xin LI. Characterization and Analysis of DOM in Raw Water in Xiamen and Zhangzhou by 3-DEEM-FRI[J]. Spectroscopy and Spectral Analysis, 2021, 41(2): 499 Copy Citation Text show less

    Abstract

    3-DEEM fluorescence spectroscopy and original fluorescence integration (3DEEM-FRI) analysis were adopted to analyze the correlation between the normalized fluorescent integral volumes and the fluorescence characteristics of the dissolved organic matter (DOM) in the raw water from reservoirs in Xiamen and Zhangzhou. The results showed that the components of aromatic protein (Component Ⅰ, C1 and Component Ⅱ, C2) and the fulvic acid (Component Ⅲ, C3) were significantly detected in all water samples. The component of soluble microbial metabolites (Component Ⅳ, C4) were detected in the water sample of Lianhua reservoir, Bantou reservoir and Shidou reservoir, while the component of humic acid (Component Ⅴ, C5) were not found obviously in any of the water samples. The relative contents of the same component are similar in different water samples. The proportion of aromatic protein components (P1, n+P2, n) is larger than 60%. The proportion of fulvic acid components (P3, n) is between 10% and 20%, as well as microbial metabolites components (P4, n), while the proportion of humic acid components (P5, n) is lower than 6%. The fluorescence characteristic parameters (1.28β∶α<0.97) demonstrated that the sources of DOM had typical pollution characteristics of mixed input from terrestrial and autogenous, and there is a homology between the CⅠ, CⅡ and CⅣ. The linear relation ship between TOC and the total normalized fluorescent integral volumes (ФT, n) is significant (R2=0.979 34), and NH4+-N showed good correlation with the normalized fluorescent integral volumes of microbial metabolites components (Ф4, n)(R2=0.827 98). The R2 between the (P3, n+P5, n) and SUVA are 0.703 25. This study demonstrated that 3-DEEM-FRI analysis could not only be used to analyze the compositions and pollutant source of the DOM, but also track and indicate the contents of TOC, NH4+-N and the humification degree of raw water effectively.
    Yan-jie CHEN, Yu-qian CUI, Qing-song LI, Bo-qiang LI, Ji-ping WANG, Guo-yuan CHEN, Jie LIAO, Guo-xin LI. Characterization and Analysis of DOM in Raw Water in Xiamen and Zhangzhou by 3-DEEM-FRI[J]. Spectroscopy and Spectral Analysis, 2021, 41(2): 499
    Download Citation