• Acta Optica Sinica
  • Vol. 40, Issue 4, 0412002 (2020)
Lei Zhao, Jian Bai*, and Weidong Fang
Author Affiliations
  • State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou, Zhejiang 310027, China
  • show less
    DOI: 10.3788/AOS202040.0412002 Cite this Article Set citation alerts
    Lei Zhao, Jian Bai, Weidong Fang. Focal Length Measurement Method for Lenses with Small Aperture and Long Focal Length[J]. Acta Optica Sinica, 2020, 40(4): 0412002 Copy Citation Text show less
    References

    [1] Chen W, Liang Z C, Ge L et al. Micro-optics label system based on six-reflection fold annular aperture lens[J]. Laser & Optoelectronics Progress, 54, 062201(2017).

    [2] Ma X K. Error analysis of measuring focal length of convex lens by object-image interchange method[J]. Physics Experimentation, 9, 258-260(1989).

    [3] Mu G G, Zhan Y L[M]. Optics(1978).

    [4] Meshcheryakov V I, Sinelnikov M I, Filippov O K. Measuring the focal lengths of long-focus optical systems[J]. Journal of Optical Technology, 66, 458-459(1999).

    [5] Parham T. McCarville T J, Johnson M A, et al. Focal length measurements for the national ignition facility large lenses. [C]//Optical Fabrication and Testing, June 3-5, 2002, Tucson, Arizona, United States. Washington, D.C.: OSA, OWD8(2002).

    [6] Zhao W Q, Sun R D, Qiu L R et al. Laser differential confocal ultra-long focal length measurement[J]. Optics Express, 17, 20051-20062(2009).

    [7] Yokozeki S, Kusaka Y, Patorski K. Geometric parameters of moiré fringes[J]. Applied Optics, 15, 2223-2227(1976).

    [8] Nakano Y, Murata K. Measurements of phase objects using the Talbot effect and moiré techniques[J]. Applied Optics, 23, 2296-2299(1984).

    [9] Hou C L, Bai J, Hou X Y et al. The measurement of long focal length based on Talbot effect of Ronchi grating[J]. Acta Optica Sinica, 22, 1328-1330(2002).

    [10] Luo J, Bai J, Zhang J C et al. Long focal-length measurement using divergent beam and two gratings of different periods[J]. Optics Express, 22, 27921-27931(2014).

    [11] Luo J. Study on large-aperture lens detection techniques based on wavefront sensing[D]. Hangzhou: Zhejiang University(2016).

    [12] Jin X R. Calibration methods for long focal-length measurement with Talbot interferometry[D]. Hangzhou: Zhejiang University(2013).

    Lei Zhao, Jian Bai, Weidong Fang. Focal Length Measurement Method for Lenses with Small Aperture and Long Focal Length[J]. Acta Optica Sinica, 2020, 40(4): 0412002
    Download Citation