    Abstract

    Based on the principles of radiometry and consideration of receiving size of the detector, the method now being used to calculate narcissus induced temperature difference is corrected. It can be used to evaluate the narcissus effects during optical design process and also to provide narcissus criteria for thermal imaging systems.
    [in Chinese]. Corrected Calculation of Narcissus Induced Temperature Difference in Scanned Infrared Imaging Systems[J]. Acta Optica Sinica, 1997, 17(1): 126