    DOI: 10.12086/oee.2021.210038 Cite this Article
    Yin Shiyu, Guo Hao, Yan Min, Wang Zhigang, Ma Lishuang, Zhang Lingfeng, Qian Sen. Study on performance test plan of inorganic scintillator[J]. Opto-Electronic Engineering, 2021, 48(6): 210038 Copy Citation Text show less
    References

    [3] Zhu Y, Wang Z G, Qian S, et al. Study of characteristics of Ce-doped Gd3Al2Ga3O12 scintillator[C]//Proceedings of 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference, 2019.

    [5] Huang X Y, Lamperstorfer A S, Tsai Y L S, et al. Perspective of monochromatic gamma-ray line detection with the High Energy cosmic-Radiation Detection (HERD) facility onboard China's Space Station[J]. Astropart Phys, 2016, 78: 35–42.

    [7] Mao R H, Wu C, Dai L E, et al. Crystal growth and scintillation properties of LSO and LYSO crystals[J]. J Cryst Growth, 2013, 368: 97–100.

    [8] Phunpueok A, Chewpraditkul W, Limsuwan P, et al. Light output and energy resolution of Lu0.7Y0.3AlO3:Ce and Lu1.95Y0.05SiO5:Ce scintillators[J]. Proced Eng, 2012, 32: 564–570.

    [9] Ferri A, Gola A, Serra N, et al. Performance of FBK high-density SiPM technology coupled to Ce:LYSO and Ce:GAGG for TOF-PET[J]. Phys Med Biol, 2014, 59(4): 869–880.

    [10] Calva-Coraza E, Alva-Sánchez H, Murrieta-Rodríguez T, et al. Optimization of a large-area detector-block based on SiPM and pixelated LYSO crystal arrays[J]. Phys Med, 2017, 42: 19.

    [11] Alva-Sanchez H, Murrieta T, Moreno-Barbosa E, et al. A small-animal PET system based on LYSO crystal arrays, PS-PMTs and a PCI DAQ board[J]. IEEE Trans Nucl Sci, 2010, 57(1): 85–93.

    [12] Akatsu M, Enari Y, Hayasaka K, et al. MCP-PMT timing property for single photons[J]. Nucl Instrum Meth Phys Res, 2004, 528(3): 763–775.

    [13] https://www.hamamatsu.com/jp/en/product/optical-sensors/mppc/index.html.

    [14] Tamulaitis G, Auffray E, Gola A, et al. Improvement of the timing properties of Ce-doped oxyorthosilicate LYSO scintillating crystals[J]. J Phys Chem Solids, 2020, 139: 109356.

    [15] Zhu Y, Qian S, Wang Z G, et al. Scintillation properties of GAGG:Ce ceramic and single crystal[J]. Opt Mater, 2020, 105: 109964.

    [16] Deprez K, Van Holen R, Vandenberghe S. A high resolution SPECT detector based on thin continuous LYSO[J]. Phys Med Biol, 2014, 59(1): 153–171.

    [17] Atanov N, Baranov V, Colao F, et al. Energy and time resolution of a LYSO matrix prototype for the Mu2e experiment[J]. Nucl Instrum Methods Phys Res Sec A: Accel, Spectrom, Detect Assoc Equip, 2016, 824: 684–685.

    [18] Wanarak C, Chewpraditkul W, Phunpueok A, et al. Luminescence and scintillation properties of Ce-doped LYSO and YSO crystals[J]. Adv Mater Res, 2011, 199–200: 1796–1803.

    [20] Martins A F, Carreira J F C, Rodrigues J, et al. Spectroscopic analysis of LYSO:Ce crystals[J]. Spectrochim Acta Part A: Mol Biomol Spectrosc, 2017, 172: 163–167.

    [21] Iwanowska J, Swiderski L, Szczesniak L, et al. Performance of cerium-doped Gd3Al2Ga3O12(GAGG:Ce) scintillator in gamma-ray spectrometry[J]. Nucl Instrum Methods Phys Res Sec A: Accel, Spectrom, Detect Assoc Equip, 2013, 712: 34–40.

    [23] Tong Y, Yan Z W, Zeng H D, et al. Enhanced blue emission of SnO2 doped phosphate glasses by Gd2O3 co-doping[J]. J Lumin, 2014, 145: 438–442.

    [26] Kotera K, Choi W, Takeshita T. SiPM response functions representing wide range including linear behavior after saturation[Z]. arXiv:1510.01102, 2016.

    [27] Eigen G, Lee G R. Light yield and uniformity measurements of different scintillator tiles with silicon photomultipliers[J]. J Instrum, 2020, 15(6): C06059.

    [28] Limkitjaroenporn P, Sangwaranatee N, Chaiphaksa W, et al. Comparative studies of the light yield non-proportionality and energy resolution of CsI(Tl), LYSO and BGO scintillation crystals[J]. Mater Sci Forum, 2016, 872: 266–270.

    [29] http://www.hamamatsu.com.cn/UserFiles/DownFile/Product/R6427_R7056_TPMH1187E05.pdf.

    [30] http://lmu.web.psi.ch/docu/manuals/bulk_manuals/PMTs/xp2020.pdf.

    [31] Pan T, Einstein S A, Kappadath S C, et al. Performance evaluation of the 5‐Ring GE Discovery MI PET/CT system using the national electrical manufacturers association NU 2‐2012 Standard[J]. Med Phys, 2019, 46(7): 3025–3033.

    [32] https://www.mouser.cn/datasheet/2/308/MICROJ-SERIES-D- 1811589.pdf.

    Yin Shiyu, Guo Hao, Yan Min, Wang Zhigang, Ma Lishuang, Zhang Lingfeng, Qian Sen. Study on performance test plan of inorganic scintillator[J]. Opto-Electronic Engineering, 2021, 48(6): 210038