• Infrared and Laser Engineering
  • Vol. 52, Issue 9, 20230024 (2023)
Cong Pan1、2、3, Yu Ye1、2, Bozhong Gu1、2, and Yulin Shuai1、2、3
Author Affiliations
  • 1Nanjing Institute of Astronomical Optics & Technology, Chinese Academy of Sciences, Nanjing 210042, China
  • 2CAS Key Laboratory of Astronomical Optics & Technology, Nanjing Institute of Astronomical Optics & Technology, Nanjing 210042, China
  • 3University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.3788/IRLA20230024 Cite this Article
    Cong Pan, Yu Ye, Bozhong Gu, Yulin Shuai. Temperature control of extinction tube for the 2.5-meter large-field and high-resolution telescope[J]. Infrared and Laser Engineering, 2023, 52(9): 20230024 Copy Citation Text show less
    Principle of the temperature control system of the extinction tube
    Fig. 1. Principle of the temperature control system of the extinction tube
    Model identification experimental device diagram of matting cylinder temperature control system
    Fig. 2. Model identification experimental device diagram of matting cylinder temperature control system
    Comparison of model response from experiment and recognition
    Fig. 3. Comparison of model response from experiment and recognition
    Schematic of the Smith predictor
    Fig. 4. Schematic of the Smith predictor
    Block diagram of ADRC-Smith controller
    Fig. 5. Block diagram of ADRC-Smith controller
    Response curves of different controllers when the model is accurate
    Fig. 6. Response curves of different controllers when the model is accurate
    Response curves of different controllers when the model is offset
    Fig. 7. Response curves of different controllers when the model is offset
    Matting cylinder temperature control system interface
    Fig. 8. Matting cylinder temperature control system interface
    (a) Tracking environmental temperature curve of ADRC-Smith; (b) Tracking environmental temperature curve of PID-Smith
    Fig. 9. (a) Tracking environmental temperature curve of ADRC-Smith; (b) Tracking environmental temperature curve of PID-Smith
    ADRC-Smith controller response curve under heat source interference
    Fig. 10. ADRC-Smith controller response curve under heat source interference
    ControllerResponds time/s Setting time/s Steady-state error RMS/℃
    ADRC-Smith591730.14
    PID-Smith513490.49
    Table 1. Performance comparison of different controllers
    Cong Pan, Yu Ye, Bozhong Gu, Yulin Shuai. Temperature control of extinction tube for the 2.5-meter large-field and high-resolution telescope[J]. Infrared and Laser Engineering, 2023, 52(9): 20230024
    Download Citation