• Infrared and Laser Engineering
  • Vol. 47, Issue 5, 504001 (2018)
Long Liang, Zhang Lisha, and Wu Limin
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/irla201847.0504001 Cite this Article
    Long Liang, Zhang Lisha, Wu Limin. Testing technique of ultra-high sensitivity long-wave infrared camera[J]. Infrared and Laser Engineering, 2018, 47(5): 504001 Copy Citation Text show less
    References

    [1] GB-T 17444-2013.Technical manual of IRFPA characteristic parameters test[S], 2013. (in Chinese)

    [2] Wei Dong, Xu Shiwei, Wang Dapeng. Comparison and analysis on NETD testing of infrared system[J]. Electro-Optic Technology Applicationg, 2012, 27(6): 38-41. (in Chinese)

    [3] Chu Hua, Wan Qiang, Li Wei, et al. Engineering measurement method of NETD for thermal infrared imager[J]. Laser & Infrared, 2016, 46(12): 1496-1499. (in Chinese)

    [4] Liu Bin, Wang Jie, Dong Jianting. Parameters test of long wave infrared imaging system based on 512×6 TDI detector[J]. Semiconductor Optoelectronics, 2016, 37(3): 430-434. (in Chinese)

    [5] Tian Qijie, Chang Songtao, Qiao Yanfeng, et al. Radiometric calibration based on low-temperature area blackbody for infrared systems with high dynamic range[J]. Acta Photonica Sinica, 2017, 46(4): 0412003. (in Chinese)

    [6] Lai Fuwen, Zhang Zhijie, Zhou Hanchang, et al. Measurement and analysis of noise equivalent temperature difference Based on high temperature background[J]. Infrared Technology, 2015(4): 311-313. (in Chinese)

    [7] Long Liang, Wang Shitao, Zhou Feng. Research on calculation method of space remote sensor′s radiometric calibration accuracy[J]. Spacecraft Recovery & Remote Sensing, 2012, 33(6): 51-55. (in Chinese)

    [8] Sha Dingguo. Error Analysis and Measurement Uncertainty Evaluation[M]. Beijing: China Metrology Publishing House, 2006: 124-151. (in Chinese)

    [9] Guo Lihong, Guo Hanzhou, Yang Ciyin, et al. Improvement of radiation measurement precision for target by using atmosphere-corrected coefficients [J]. Optics and Precision Engineering, 2016, 24(8): 1871. (in Chinese)

    [10] Zhang Xiaolong, Liu Ying, Sun Qiang. Radiometric calibration of uncooled long-wave infrared thermal imager with high-precision[J]. Chinese Optics, 2012, 5(3): 235-241. (in Chinese)

    [11] An Chengbin, Wan Ying. Analysis of NETD test for thermal imaging system[J]. Infrared and Laser Engineering, 2010, 39(3): 414-417. (in Chinese)

    [12] Li Yingwen, Chen Fusheng, Yang Changcheng, et al. Introduction to infrared test standard transferd test standard transter[J]. Infrared and Laser Engineering, 2007, 36(z1): 119-123. (in Chinese)

    [13] Zou Qianjin, Liu Lianwei, Chen Qianrong, et al. Calibration experiments of infrared detecting system with fixed focal length[J]. Infrared and Laser Engineering, 2016, 45(12): 1204004. (in Chinese)

    [14] Wu Xueming, Wang Haiyan, Kou Tian, et al. Test of infrared search and track system[J]. Infrared and Laser Engineering, 2017, 46(5): 0504003. (in Chinese)

    Long Liang, Zhang Lisha, Wu Limin. Testing technique of ultra-high sensitivity long-wave infrared camera[J]. Infrared and Laser Engineering, 2018, 47(5): 504001
    Download Citation