• Chinese Journal of Lasers
  • Vol. 41, Issue 7, 708001 (2014)
Hu Jinzhong*, Yu Xiaofen, Ren Xing, and Zhao Da
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/cjl201441.0708001 Cite this Article Set citation alerts
    Hu Jinzhong, Yu Xiaofen, Ren Xing, Zhao Da. Optimal Layout of Three-Dimensional Coordinate Measurement System Based on Laser Multi-Lateration[J]. Chinese Journal of Lasers, 2014, 41(7): 708001 Copy Citation Text show less

    Abstract

    The measurement accuracy of the three-dimensional (3D) coordinate measuring system based on laser multi-lateration is influenced by its layout. In previous study, the system′s layout is optimized for the tri-rectangular pyramid layout by theoretical analysis of the non-target self-calibration model. On this basis, through error analysis of the linearized measurement model of the system, it is found that the optimal layout, that is the tri-rectangular regular pyramid layout, is obtained, when the condition number of the coefficient matrix of the measurement model achieves minimum. Simulation results show that the tri-rectangular regular pyramid layout can efficiently ensure the accuracy of the system.
    Hu Jinzhong, Yu Xiaofen, Ren Xing, Zhao Da. Optimal Layout of Three-Dimensional Coordinate Measurement System Based on Laser Multi-Lateration[J]. Chinese Journal of Lasers, 2014, 41(7): 708001
    Download Citation