• Acta Optica Sinica
  • Vol. 39, Issue 3, 0311001 (2019)
Yongqiang Sun, Yuan Hu*, Yueqi Wang, Qi Wang, and Yuegang Fu
Author Affiliations
  • Key Laboratory of Opto-Electronic Measurement and Optical Information Transmission Technology, Ministry of Education, Changchun University of Science and Technology, Changchun, Jilin 130022, China
  • show less
    DOI: 10.3788/AOS201939.0311001 Cite this Article Set citation alerts
    Yongqiang Sun, Yuan Hu, Yueqi Wang, Qi Wang, Yuegang Fu. Analysis on Aberration of Digital Micromirror Device in Convergent Imaging Path[J]. Acta Optica Sinica, 2019, 39(3): 0311001 Copy Citation Text show less
    Optical path diagram of DMD and equivalent mirror in convergent light path
    Fig. 1. Optical path diagram of DMD and equivalent mirror in convergent light path
    Optical path diagram of two working states for one DMD micromirror
    Fig. 2. Optical path diagram of two working states for one DMD micromirror
    Relationship between optical path difference DOP caused by DMD and image height h on DMD
    Fig. 3. Relationship between optical path difference DOP caused by DMD and image height h on DMD
    Residual OPD curve after image plane tilt
    Fig. 4. Residual OPD curve after image plane tilt
    Schematic of experimental optical path of aberration verification for DMD under normal incidence. (a) Optical path diagram for mirror with deflection of 12°; (b) optical path diagram for DMD under normal incidence
    Fig. 5. Schematic of experimental optical path of aberration verification for DMD under normal incidence. (a) Optical path diagram for mirror with deflection of 12°; (b) optical path diagram for DMD under normal incidence
    Experimental optical path of aberration verification for DMD under normal incidence. (a) Convergent imaging light path with mirror; (b) convergent imaging light path of DMD
    Fig. 6. Experimental optical path of aberration verification for DMD under normal incidence. (a) Convergent imaging light path with mirror; (b) convergent imaging light path of DMD
    Experimental results of aberration verification for DMD under normal incidence. (a) Cross wires under plane mirror; (b) cross wires under DMD; (c) experimental result of OPD compensation by image plane tilt
    Fig. 7. Experimental results of aberration verification for DMD under normal incidence. (a) Cross wires under plane mirror; (b) cross wires under DMD; (c) experimental result of OPD compensation by image plane tilt
    Yongqiang Sun, Yuan Hu, Yueqi Wang, Qi Wang, Yuegang Fu. Analysis on Aberration of Digital Micromirror Device in Convergent Imaging Path[J]. Acta Optica Sinica, 2019, 39(3): 0311001
    Download Citation