• Acta Optica Sinica
  • Vol. 35, Issue 8, 811002 (2015)
Bai Caixun*, Li Jianxin, Meng Xin, Shen Yan, and Zhu Rihong
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos201535.0811002 Cite this Article Set citation alerts
    Bai Caixun, Li Jianxin, Meng Xin, Shen Yan, Zhu Rihong. Hyperspectral Imaging Based on Symmetric Wedgy Interferometric Cavity[J]. Acta Optica Sinica, 2015, 35(8): 811002 Copy Citation Text show less
    References

    [1] Cabib D,Buckwald R A,Garini Y,et al..Spatially resolved Fourier transform spectroscopy (spectral imaging):A powerful tool for quantitative analytical microscopy[C].SPIE,1996,2678:278-291.

    [2] Harvey A R,Holmes D W F.Birefringent Fourier-transform imaging spectrometer [J].Optics Express,2004,22(12):5368-5374.

    [3] Horton R F.Optical design for a high etendue imaging Fourier transform spectrometer[C].SPIE,1996,2819:300-315.

    [4] Posselt W,Holota K,Tittel H O,et al..Compact fourier transform imaging spectrometer for remote sensing[C].Fourier Transform Spectroscopy (FTS),2001,FMD10.

    [5] Dong Ying,Xiang Libin,Zhao Baochang.Lateral shearing interferometer in large aperture static imaging spectrometer[J].Acta Photonica Sinica,1999,28(11):991-995.

    [6] Li Jianxin,Meng Xin,Zhou Wei,et al..Image plane interferometric hyperspectral imaging based on re-imaging[J].Acta Optica Sinica,2012,32(12):1230001.

    [7] Meng Xin,Li Jianxin,Zhu Rihong,et al..Compressive sampling recovery method of narrow-band hyperspectral interferometric imaging [J].Acta Optica Sinica,2012,33(1):0130001.

    [8] Li Jianxin,Zhou Wei,Meng Xin,et al..Hyperspectral microscopic imaging based on image plane interferometry[J].Acta Optica Sinica,2013,33(12):1211005.

    [9] Jian Xiaohua,Zhang Chunmin,Sun Yao,et al..Novel polarization interference imaging spectrometer with adjustable lateral displacement savart polariscope[J].Acta Optica Sinica,2007,27(4):643-646.

    [10] Xiang Libin,Yuan Yan,Lü Qunbo.Spectral transfer function of the Fourier transform spectral imager[J].Acta Physica Sinica,2009,58(8):5399-5405.

    [11] Li Suning,Zhu Rihong,Gao Zhishan,et al..Fourier conjugate correction spectral reconstruction for Fourier-transform spectrometer[J].Acta Optica Sinica,2011,31(4):0412010.

    [12] Zhang Chunmin,Zhao Baochang,Xiang Libin,et al..Analysis and calculation of throughput of the polarization interference imaging spectrometer[J].Acta Optica Sinica,2001,21(2):192-197.

    [13] Zhang Chunmin,Liu Ning,Wu Fuquan.Analysis and calculation of Glan-Taylor prism's transmittance at full angle of view in a polarization interference imaging spectrometer[J].Acta Physica Sinica,2010,59(2):949-957.

    [14] Li Jie,Zhu Jingping,Zhang Yunyao,et al..Spectral zooming birefringent imaging spectrometer[J].Acta Physica Sinica,2013,62(2):024205.

    [15] Du Shusong,Wang Yongmei,Tao Ran.Multiple beam interferential spectral imaging technology[J].Acta Optica Sinica,2013,33(8):0830003.

    [16] Liu Yang,Liao Ningfang,Bai Tingzhu,et al..Study of the structure of large aperture ultraviolet Fourier transform imaging spectrometer [J].Acta Optica Sinica,2014,34(3):0330001.

    [17] Posselt W,Tittel H,Rost M,et al..The imaging FT spectrometer FTIS[C].Fourier Transform Spectroscopy (FTS),2003:FMB2.

    [18] Lucey P G,Akagi J.A Fabry-Perot interferometer with a spatially variable resonance gap employed as a Fourier transform spectrometer [C].SPIE,2011,8048:80480K.

    [19] Pisani M,Zucco M.Compact imaging spectrometer combining Fourier transform spectroscopy with a Fabry-Perot interferometer[J].Optics Express,2009,17(10):8319-8331.

    [20] Antila J,Mannila R,Kantojarvi U,et al..Spectral imaging device based on a tuneable MEMS Fabry-Perot interferometer [C].SPIE,2012,8374:83740F.

    [21] Meng Xin,Li Jianxin,Zhu Rihong,et al..Near-field mechanism research on hyperspectral image plane interferometric imaging[J].Acta Optica Sinica,2013,33(2):0230001.

    [22] Zhang Chunmin,Zhao Baochang,Xiang Libin.Influence of polarized direction on modulation depth of a polarization interference imaging spectrometer[J].Acta Optica Sinica,2000,20(8):1077-1083.

    [23] Fu Qiang,Xiang Libin,Jing Juanjuan,et al..Design of a dual-channel Mach-Zehnder lateral shearing interferometer for the largeaperture static imaging spectrometer[J].Spectroscopy and Spectral Analysis,2012,32(2):553-557.

    [24] Born M,Wolf E.Principles of Optics[M].Beijing:Electronic Industry Press,2009:324-333.

    [25] Kajava T T,Lauranto H M,Friberg A T.Interference pattern of the Fizeau interferometer[J].JOSA A,1994,11(7):2045-2054.

    [26] Gillard F,Ferrec Y,Guerineau N,et al..Angular acceptance analysis of an infrared focal plane array with a built-in stationary Fourier transform spectrometer[J].JOSA A,2012,29(6):936-944.

    [27] Xu Jinyong,Sun Peijia.Optics Designing[M].Beijing:National Defence Industry Press:1989:59-61.

    CLP Journals

    [1] Li Jianxin, Liu Qin, Zhou Jianqiang, Bai Caixun, Xu Yixuan, Yuan Heng, Liu Jie. Optimal Design for Broadband Polarization State Analyzer of Ferroelectric Liquid Crystal[J]. Acta Optica Sinica, 2017, 37(7): 726002

    [2] Bai Caixun, Li Jianxin, Meng Xin, Zhou Jianqiang, Shen Yan, Wang Hao. Spectrum Recovery Method for Hyperspectral Imaging Based on Symmetric Wedgy Interferometric Cavity[J]. Acta Optica Sinica, 2016, 36(2): 230004

    Bai Caixun, Li Jianxin, Meng Xin, Shen Yan, Zhu Rihong. Hyperspectral Imaging Based on Symmetric Wedgy Interferometric Cavity[J]. Acta Optica Sinica, 2015, 35(8): 811002
    Download Citation