• Laser & Optoelectronics Progress
  • Vol. 55, Issue 8, 80701 (2018)
Lü Wei, Cai Zhiqiang, and Chu Jinghui*
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/lop55.080701 Cite this Article Set citation alerts
    Lü Wei, Cai Zhiqiang, Chu Jinghui. Load Identification Based on S-Transform and (2D)2PCA of Transient Current[J]. Laser & Optoelectronics Progress, 2018, 55(8): 80701 Copy Citation Text show less
    References

    [1] Xu Z R, Yang P, Zhao Z L, et al. Analysis on the development of multi-microgrid in China[J]. Automation of Electric Power Systems, 2016, 40(17): 224-231.

    [2] Hart G W. Nonintrusive appliance load monitoring[J]. Proceedings of the IEEE, 1992, 80(12): 1870-1891.

    [3] Drenker S, Kader A. Nonintrusive monitoring of electric loads[J]. IEEE Computer Applications in Power, 1999, 12(4): 47-51.

    [4] Srinivasan D, Ng W S, Liew A C. Neural-network-based signature recognition for harmonic source identification[J]. IEEE Transactions on Power Delivery, 2006, 21(1): 398-405.

    [5] Lam H Y, Fung G S K, Lee W K. A novel method to construct taxonomy electrical appliances based on load signatures[J]. IEEE Transactions on Consumer Electronics, 2007, 53(2): 653-660.

    [6] Gupta S, Reynolds M S, Patel S N. ElectriSense: single-point sensing using EMI for electrical event detection and classification in the home[C]∥ACM International Conference on Ubiquitous Computing, ACM, 2010: 139-148.

    [7] Lou J L, Yu H T, Qu Z Y. Load decomposition method for non-intrusive household system[J]. Journal of Jilin University (Science Edition), 2015, 53(4): 744-753.

    [8] Sun Y, Cui C,Lu J, et al. Non-intrusive load monitoring method based on delta feature extraction and fuzzy clustering[J]. Automation of Electric Power Systems, 2017, 41(4): 86-91.

    [9] Zhu C H, Wang J P, Li Q Y, et al. Recognition and localization of intrusion vibration signal based on time-frequency characteristics in optical fiber perimeter security[J]. Chinese Journal of Lasers, 2016, 43(6): 0610001.

    [10] Tan Z, Xiangli B, Lü Q B, et al. A sequence images super-resolution enhancement approach based on frequency-domain[J]. Acta Optica Sinica, 2017, 37(7): 0710001.

    [11] Cox R, Leeb S B, Shaw S R, et al. Transient event detection for nonintrusive load monitoring and demand side management using voltage distortion[C]∥21st Annual IEEE Applied Power Electronics Conference and Exposition, IEEE, 2006: 1751-1757.

    [12] Patel S N, Robertson T, Kientz J A, et al. At the flick of a switch: detecting and classifying unique electrical events on the residential power line[C]∥International Conference on Ubiquitous Computing, Springer, 2007: 271-288.

    [13] Saitoh T, Aota Y, Osaki T, et al. Current sensor based non-intrusive appliance recognition for intelligent outlet[C]∥23rd International Technical Conference on Circuits/Systems, Computers and Communications, 2008: 349-352.

    [14] Martins J F, Lopes R, Lima C, et al. A novel nonintrusive load monitoring system based on the S-transform[C]∥13th International Conference on Optimization of Electrical and Electronic Equipment, IEEE, 2012: 973-978.

    [15] Lin Y H, Tsai M S. Development of an improved time-frequency analysis-based nonintrusive load monitor for load demand identification[J]. IEEE Transactions on Instrumentation and Measurement, 2014, 63(6): 1470-1483.

    [16] Ahmadi H, Marti J R. Load decomposition at smart meters level using eigenloads approach[J]. IEEE Transactions on Power Systems, 2015, 30(6): 3425-3436.

    [17] Li Y X. Research on algorithms of non-intrusive load decomposition[D]. Beijing: Beijing Jiaotong University, 2016.

    [18] Zhang D, Zhou Z H. (2D)2PCA: two-directional two-dimensional PCA for efficient face representation and recognition[J]. Neurocomputing, 2005, 69(1): 224-231.

    [19] Sun C X, Pan J X, Chen P. Segmental multi-energy computed tomography imaging based on wavelet analysis[J]. Laser & Optoelectronics Progress, 2016, 53(9): 093401.

    [20] Tsai M S, Lin Y H. Modern development of an adaptive non-intrusive appliance load monitoring system in electricity energy conservation[J]. Applied Energy, 2012, 96: 55-73.

    [21] Stockwell R G, Mansinha L, Lowe R P. Localization of the complex spectrum: the S-transform[J]. IEEE Transactions on Signal Processing, 1996, 44(4): 998-1001.

    Lü Wei, Cai Zhiqiang, Chu Jinghui. Load Identification Based on S-Transform and (2D)2PCA of Transient Current[J]. Laser & Optoelectronics Progress, 2018, 55(8): 80701
    Download Citation