• Acta Optica Sinica
  • Vol. 29, Issue 9, 2590 (2009)
Wang Shurong1、*, Li Futian1, Song Kefei1, Wang Lipeng1, Wang Longqi1, Lin Guanyu1, Huang Yu1, Huang Fuxiang2, and Wang Weihe2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/aos20092909.2590 Cite this Article Set citation alerts
    Wang Shurong, Li Futian, Song Kefei, Wang Lipeng, Wang Longqi, Lin Guanyu, Huang Yu, Huang Fuxiang, Wang Weihe. Ultrariolet Ozone Vertical Profile Probe for FY-3A Meteorological Satellite[J]. Acta Optica Sinica, 2009, 29(9): 2590 Copy Citation Text show less
    References

    [1] D. F. Heath, A. J. Krueger, H. A. Roeder et al.. The solar backscatter ultraviolet and total ozone mapping spectrometer (SBUV/TOMS) for Nimbus G[J]. Optical Engineering, 1975, 14: 323-331

    [2] H. Weiss, R. P. Cebula, K. Laamann et al.. Evaluation of the NOAA-11 backscatter ultraviolet radiometer, mod(SBUV/2):inflight calibration[C]. SPIE, 1991, 1493: 80-90

    [3] Wei Zongying, Kevin. W. Kelly. BRDF Measurement and calibration for SBUV/2 radiance calibration test tiffuser[C]. SPIE, 2004, 5542: 311-3223

    [4] S. P. Ahmad, P. F. Levelt, P. K. Bhartia et al.. Atmospheric products from the ozone monitoring instrument (OMI)[C]. SPIE, 2003, 5151: 619-631

    [5] Solar spectral irradiance (SSI) data. http: //lasp. colorado. edu/sorce/ssi_data

    CLP Journals

    [1] Yang Xiaohu, Wang Shurong, Huang Yu. Spectral Irradiance Calibration Research of the Solar Backscattered Ultraviolet Spectroradiometer in Air/Vacuum Conditions[J]. Acta Optica Sinica, 2012, 32(1): 101004

    [2] Li Zhanfeng, Wang Shurong, Huang Yu, Yu Xiangyang. Research on High-Accuracy in-Flight Spectral Calibration of the Solar Backscattered Ultraviolet Spectroradiometer[J]. Acta Optica Sinica, 2013, 33(2): 228002

    [3] DU Guo-jun, LIAO Zhi-bo, HOU Li-zhou. Progress of Grating Spectrometer for Space Detection[J]. Journal of Atmospheric and Environmental Optics, 2014, 9(5): 329

    [4] Xue Qingsheng. Optical System Design of Multi-Model Hyperspectral Imager for Spaced-Based Atmospheric Remote Sensing[J]. Acta Optica Sinica, 2014, 34(8): 822005

    [5] Wang Hongbo, Hu Xiuqing, Zhang Lu3, Zhang Chongbing, Ren Baichuan, Huang Xiaoxian, Wei Jun. Polarization Correction for Grating Dispersive Imaging Spectrometer[J]. Acta Optica Sinica, 2016, 36(8): 812004

    [6] XUE Qing-sheng, LI Yang, DUAN Min-zheng. Optical Design of Space-based UV Panoramic Sounder for Nadir and Limb Viewing[J]. Acta Photonica Sinica, 2015, 44(5): 522001

    [7] Wang Rui, Wang Shurong, Guo Jin, Wang Tingfeng, Zhang Zhenduo. High-Accuracy Ultraviolet Standard Radiometer[J]. Acta Optica Sinica, 2011, 31(4): 404001

    [8] Li Zhanfeng, Wang Shurong, Huang Yu, Lin Guanyu. A Method on Measurement of Mueller Matrix Elements for Polarization Correction[J]. Acta Optica Sinica, 2013, 33(6): 628001

    Wang Shurong, Li Futian, Song Kefei, Wang Lipeng, Wang Longqi, Lin Guanyu, Huang Yu, Huang Fuxiang, Wang Weihe. Ultrariolet Ozone Vertical Profile Probe for FY-3A Meteorological Satellite[J]. Acta Optica Sinica, 2009, 29(9): 2590
    Download Citation