• Infrared and Laser Engineering
  • Vol. 45, Issue 8, 824003 (2016)
Peng Hongtao1、*, Yang Zhaohua1, Li Dapeng1, and Wu Ling′an2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/irla201645.0824003 Cite this Article
    Peng Hongtao, Yang Zhaohua, Li Dapeng, Wu Ling′an. Experimental study on effect of focal length on quality of computational ghost imaging[J]. Infrared and Laser Engineering, 2016, 45(8): 824003 Copy Citation Text show less

    Abstract

    Conventional optical imaging require the image plane at the focal plane of the imaging lens group to get the maximum flux. So the focal length has great impact on imaging quality. In order to investigate the influence of focal length on quality of computational ghost imaging, the experiment of computational ghost imaging was constructed, and the probability density of the measurement of bucket detector was utilized to analyze the results of computational ghost imaging with different focal length and background light. The results show that the variation of focal length and background light have little effect on the quality of computational ghost imaging, which solve the problem that the defocus lead to the deterioration of quality caused by the inequality of two optical path in traditional ghost imaging. Computational ghost imaging can be realized without imaging lens and only using a bucket detector, thus avoiding the allocation of flux on the pixel dimension as well as improving the signal-to-noise ratio. Therefore, computational ghost imaging is very suitable for imaging detection under the extremely weak background.
    Peng Hongtao, Yang Zhaohua, Li Dapeng, Wu Ling′an. Experimental study on effect of focal length on quality of computational ghost imaging[J]. Infrared and Laser Engineering, 2016, 45(8): 824003
    Download Citation