• Acta Optica Sinica
  • Vol. 36, Issue 7, 712002 (2016)
Wang Lihua*, Wu Shibin, Yang Wei, and Ren Ge
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos201636.0712002 Cite this Article Set citation alerts
    Wang Lihua, Wu Shibin, Yang Wei, Ren Ge. Analysis of Stitched Fresnel Lens Segmented Mirrors Miss-Adjustment Error[J]. Acta Optica Sinica, 2016, 36(7): 712002 Copy Citation Text show less
    References

    [1] Zhang wei, Deng Jian, Long Funian, et al. Image quality evaluation for segmented mirror synthetic aperture optics[J]. Acta Optica Sinica, 2008, 28(4): 687-691.

    [2] Zhang Nan, Lu Zhenwu, Li Fengyou. Optical design of diffractive telescope[J]. Laser & Infrared, 2007, 36(1): 106-108.

    [3] Hyde R A, Dixit S N, Weisberg A H, et al. Eyeglass: a very large aperture diffractive space telescope[C]. SPIE, 2002, 4849: 28-39.

    [4] Hawarden T G, Johnstone C, Johnstone G. GISMO, an ELT in space: a giant (30-m) far-infrared and sub-millimeter space observatory[C]. SPIE, 2004, 5382: 95-104.

    [5] Xu Yan, Yan Shuhua, Zhou Chunlei, et al. Design of hybrid reflective-diffractive telescope with very large aperture and broad bandwidth[J]. Semiconductor Optoelectronics, 2007, 28(4): 579-582.

    [6] Liu Hua, Lu Zhenwu, Yue Jinying, et al. The characteristics of compound diffractive telescope[J]. Optics Express, 2008, 16(20): 16195-16200.

    [7] Deng Jian, Zhang Wei, Zuo Baojun, et al. Misadjustment tolerance study of the sub-mirror’s for segmented mirror synthetic aperture optics[J]. Optical Technique, 2007, 33(1): 130-133.

    [8] Long Weijun, Wang Zhili, Zhou Yanping. Imaging analysis and computer simulation of optical synthetic aperture telescope[J]. Acta Optica Sinica, 2004, 24(8): 1009-1014.

    [9] Chen Rongli, Zhang Tao, Ma Zhen, et al. Influences of the alignment errors on image quality of large segmented mirrors[J]. Acta Photonica Sinica, 2009, 38(12): 3240-3244.

    [10] Wang Zhile, Zhang Wei, Long Funian. Image quality evaluation for diffraction limited optical synthetic aperture system[J]. Acta Optica Sinica, 2005, 25(1): 35-39.

    [11] Han Lihui, Deng Jian. The sub-mirror maladjustment error analysis of segmented mirror synthetic aperture optical system[J]. Laser & Infrared, 2008, 38(7): 701-704.

    [12] Yaitskova N, Dohlen K, Dierickx P. Analytical study of diffraction effects in extremely large segmented telescopes[J]. J Opt Soc Am A, 2003, 20(8): 1563-1575.

    [13] Troy M, Chanan G. Diffraction effects from giant segmented-mirror telescopes[J]. Applied Optics, 2003, 42(19): 3745-3753.

    CLP Journals

    [1] LI Taojie, WU Peng, YANG Zheng, YIN Shaoyun, DU Chunlei, WANG Yuefeng. Large Aperture Membrane Diffractive Lens Deformation Error Analysis[J]. Acta Photonica Sinica, 2018, 47(2): 205002

    [2] Wei Yang, Shibin Wu, Lihua Wang, Bin Fan, Xiangang Luo, Hu Yang. Research advances and key technologies of macrostructure membrane telescope[J]. Opto-Electronic Engineering, 2017, 44(5): 475

    [3] Wang Jinjun, Wang Xia, Ning Duo. Design of Fresnel Lens with Square Spot Uniform Concentration of Sub-Region Multi-Focus Superposition[J]. Acta Optica Sinica, 2017, 37(3): 322001

    Wang Lihua, Wu Shibin, Yang Wei, Ren Ge. Analysis of Stitched Fresnel Lens Segmented Mirrors Miss-Adjustment Error[J]. Acta Optica Sinica, 2016, 36(7): 712002
    Download Citation