• High Power Laser and Particle Beams
  • Vol. 32, Issue 2, 025013 (2020)
Hao Wei, Jiahui Yin, Pengfei Zhang, Fengju Sun, Aici Qiu, Tianxue Liang, Jiangtao Zeng, Xiaofeng Jiang, Zhiguo Wang, Jiang Sun, Wenyuan Liu, and Yixiang Hu
Author Affiliations
  • State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an 710024, China
  • show less
    DOI: 10.11884/HPLPB202032.190331 Cite this Article
    Hao Wei, Jiahui Yin, Pengfei Zhang, Fengju Sun, Aici Qiu, Tianxue Liang, Jiangtao Zeng, Xiaofeng Jiang, Zhiguo Wang, Jiang Sun, Wenyuan Liu, Yixiang Hu. Status of radiographic X-ray source driven by 4 MV, 80 kA induction voltage adder[J]. High Power Laser and Particle Beams, 2020, 32(2): 025013 Copy Citation Text show less
    References

    [4] Ekdahl C. Modern electron accelerats f radiography[C]Proc of 13th IEEE International Pulsed Power Conference. 2001: 16.

    [5] Smith I D. Induction voltage adders and the induction accelerator family[J]. Physical Review Special Topics: Accelerator and Beams, 064801(2004).

    [6] Xie Weiping. The introduction of flash Xray sources f radiography in Institute of Fluid Physics[C]Proc of 7th EuropeAsia Pulsed Power Conference High Power Particle Beams Conference. 2018.

    [7] Oliver B V. Recent advances in radiographic Xray source development at Sia[C]Proc of 17th IEEE International High Power Particle Beams Conference. 2008.

    [8] Smith I D, Bailey V L, Fockler J J. Design of a radiographic integrated test stand (RITS) based on a voltage adder, to drive a diode immersed in a high magnetic field[J]. IEEE Trans Plasma Science, 28, 1653-1659(2000).

    [9] Bayol F, re P, Garrigues A, et al. Evaluation of the rodpinch diode as a highresolution source f flash radiography at 2 to 4 MV[C]Proc of 13th IEEE International Pulsed Power Conference. 2001: 450453.

    [10] mond E C, Garcia M R, Smith J R, et al. Cygnus precision dosimetry—calibration measurements[C]Proc of 21th IEEE International Pulsed Power Conference. 2017: 569573.

    [11] Thomas K, Beech P, Brown S, et al. Status of the AWE Hydrus IVA fabrication[C]Proc of 18th IEEE International Pulsed Power Conference. 2011: 10421047.

    [12] Thomas K. The MERLIN flash radiographic accelerat[C]Proc of IEEE Pulsed Power Symposium, 2014: 129.

    [14] Wei Hao, Yin Jiahui, Zhang Pengfei. Development of a 4-MV, 80-kA induction voltage adder for flash X-ray radiography[J]. IEEE Trans Plasma Science, 47, 5030-5036(2019).

    [15] Yin Jiahui, Sun Fengju, Qiu Aici. 2.8-MV low-inductance low-jitter electrical-triggered gas switch[J]. IEEE Trans Plasma Science, 44, 2045-2052(2014).

    [16] Wei Hao, Sun Fengju, Liang Tianxue. Low voltage pulse injection test of a single-stage 1 MV prototype induction voltage adder cell[J]. Review of Scientific Instrument, 85, 064801(2014).

    Hao Wei, Jiahui Yin, Pengfei Zhang, Fengju Sun, Aici Qiu, Tianxue Liang, Jiangtao Zeng, Xiaofeng Jiang, Zhiguo Wang, Jiang Sun, Wenyuan Liu, Yixiang Hu. Status of radiographic X-ray source driven by 4 MV, 80 kA induction voltage adder[J]. High Power Laser and Particle Beams, 2020, 32(2): 025013
    Download Citation