• Optics and Precision Engineering
  • Vol. 31, Issue 9, 1295 (2023)
Yinxiao MIAO1,2, Xingyu WANG2, Hao ZHU2, Chenxing BAO2, and Jiubin TAN1,*
Author Affiliations
  • 1Institute of Ultra-precision Optoelectronic Instrument Engineering, Harbin Institute of Technology, Harbin5000, China
  • 2Beijing Aerospace Institute for Metrology and Measurement Technology, Beijing100076, China
  • show less
    DOI: 10.37188/OPE.20233109.1295 Cite this Article
    Yinxiao MIAO, Xingyu WANG, Hao ZHU, Chenxing BAO, Jiubin TAN. Model establishment and error correction of FMCW lidar[J]. Optics and Precision Engineering, 2023, 31(9): 1295 Copy Citation Text show less

    Abstract

    The geometry of frequency-modulated continuous-wave lidar deviates from that of the design model owing to the mechanical machining and assembly of the lidar. In this study, the effect of the sub-coordinate system offset and roll on the coordinate measurement accuracy of the instrument is investigated, and a correction model is developed for the geometric error of the lidar. This model can increase the measurement accuracy of the measurement system without changing the hardware structure of the system. First, a set of lidar coordinate systems is established, and the sources of spatial coordinate measurement errors are analyzed. The geometric error transfer of the measurement coordinates is achieved by applying the transformation matrix between the coordinate systems. Then, the geometric errors of the different coordinate systems are combined, and an explicit expression for the geometric spatial coordinate error of the lidar is established. Based on this, a least-squares optimization objective is established for obtaining the error factors and the corrected coordinates. The obtained error factors can be used as corrections for subsequent coordinate measurements. Finally, this method is used to design a calibration field with a laser tracker as the high-precision measurement instrument and the spherical center of the target sphere as the standard point. A system error correction experiment is performed by employing the laser tracker and lidar to evaluate the target sphere at the same position. The experimental results indicate that the average error of the lidar spatial distance measurement is reduced from 0.044 8% to 0.003 8% and the maximum error value is reduced from 4.17 to 0.30 mm after the correction, thereby confirming the effectiveness of the lidar geometric error calibration and error correction method.
    0T3=T0T1T1T1˜T1˜T2T2T2˜T2˜T3(1)

    View in Article

    3Π=T3T4-TΠ4=T1T4-TT1T3TΠ4(2)

    View in Article

    3PX|x=03PX|y=dm-dindinP3PO4|y=dm-dinsinπ4-θ2+P3P0|y3PX|z=dm-dindinP3PO4|z(3)

    View in Article

    0PX=T0T3P3PX(4)

    View in Article

    kTk^=TxkδxTykδyTzkδzRzkδαRykδβRxkδγ.(5)

    View in Article

    1^T^1˜=cosθ^1-sinθ^100sinθ^1cosθ^10000100001(6)

    View in Article

    0T3^=T0T1T1T1^T^1^T^1˜T1˜T2T2T2^T^2^T^2˜T2˜T3T3T3^(7)

    View in Article

    0PXx,y,z=fδχθ1,θ2,dm(8)

    View in Article

    δχ=[δ1δx,δ1δy,δ1δz,δ1δα,δ1δβ,δ1δγ;δ2δx,δ2δy,δ2δz,δ2δα,δ2δβ,δ2δγ;δ3δx,δ3δy,δ3δz,δ3δα,δ3δβ,δ3δγ;4δx,δ4δy,δ4δz,δ4δα,δ4δβ,δ4δγ;δθ1,δθ2].(9)

    View in Article

    0Tw,δχ=argmin0Tw,δχi=1N0Tw-1P0PXi-PwPXi2(10)

    View in Article

    δχ=argminδχi,j,ijN0PXi-P0PXj2-wPXi-PwPXj22.(11)

    View in Article

    min0Tw,δχ12i=1N0Tw-1P0PXi-PwPXi2(12)

    View in Article

    0Tw=RT0001(13)

    View in Article

    R=RzϕRyθRzψT=pxpypzT(14)

    View in Article

    min0Tw'12i=1N0Tw'-1P^0P^Xi-PwPXi2(15)

    View in Article

    Yinxiao MIAO, Xingyu WANG, Hao ZHU, Chenxing BAO, Jiubin TAN. Model establishment and error correction of FMCW lidar[J]. Optics and Precision Engineering, 2023, 31(9): 1295
    Download Citation