Zhian Wu, Xiaoyu Zhu, Jian Li**, Biao Zhang, and Chuanlong Xu*
Author Affiliations
  • National Engineering Research Center of Turbo-Generator Vibration, School of Energy and Environment, Southeast University, Nanjing, Jiangsu 210096, China
  • show less
    DOI: 10.3788/AOS202141.2010001 Cite this Article Set citation alerts
    Zhian Wu, Xiaoyu Zhu, Jian Li, Biao Zhang, Chuanlong Xu. Volumetric-Calibration Ray Tracing-Based Calculation Method of Weight Coefficient in Light Field PIV[J]. Acta Optica Sinica, 2021, 41(20): 2010001 Copy Citation Text show less
    Principle of light field imaging
    Fig. 1. Principle of light field imaging
    Principle of extracting light field subaperture image
    Fig. 2. Principle of extracting light field subaperture image
    Numerical verification diagram of weight coefficient calculation method
    Fig. 3. Numerical verification diagram of weight coefficient calculation method
    Weight coefficient atlas at different depth positions
    Fig. 4. Weight coefficient atlas at different depth positions
    Similarity of weight coefficients at different depth positions
    Fig. 5. Similarity of weight coefficients at different depth positions
    Weight construction results of calibration plate at different depth positions. (a) VCT method; (b) DRT method
    Fig. 6. Weight construction results of calibration plate at different depth positions. (a) VCT method; (b) DRT method
    Reconstruction accuracy of calibration plate dot position. (a) Location errors in lateral; (b) location errors in depth
    Fig. 7. Reconstruction accuracy of calibration plate dot position. (a) Location errors in lateral; (b) location errors in depth
    Reconstructed stretch length of calibration plate dot. (a) Lateral elongation; (b) depth elongation
    Fig. 8. Reconstructed stretch length of calibration plate dot. (a) Lateral elongation; (b) depth elongation
    Verification system of weight coefficient calculation experiment. (a) Schematic diagram; (b) physical figure
    Fig. 9. Verification system of weight coefficient calculation experiment. (a) Schematic diagram; (b) physical figure
    Cage light field camera
    Fig. 10. Cage light field camera
    Light field images of calibration plate taken at different depth positions in experiment. (a) z=-5 mm; (b) z=0; (c) z=5 mm
    Fig. 11. Light field images of calibration plate taken at different depth positions in experiment. (a) z=-5 mm; (b) z=0; (c) z=5 mm
    Reconstruction of the accuracy of position of calibration plate in experiment. (a) Location errors in lateral; (b) location errors in depth
    Fig. 12. Reconstruction of the accuracy of position of calibration plate in experiment. (a) Location errors in lateral; (b) location errors in depth
    Reconstructed stretch length of dots on reconstituted calibration plate in experiment. (a) Lateral elongation; (b) depth elongation
    Fig. 13. Reconstructed stretch length of dots on reconstituted calibration plate in experiment. (a) Lateral elongation; (b) depth elongation
    SymbolParameterValueSymbolParameterValue
    fm /mmFocal length of main lens100fl /μmFocal length of microlens800
    pm /mmMain lens aperture25pl /mmMicrolens size0.1
    MMagnification-1px /μmPixel size5.5
    dsi /mmDistance from main lens to MLA200dl /μmDistance from MLA to CCD800
    FmF number of main lens4FlF number of microlens8
    Table 1. Parameters of light field camera
    Coordinate1234567891011121314151617
    x-2.4-2.1-1.8-1.5-1.2-0.9-0.6-0.300.30.60.91.21.51.82.12.4
    y-2.4-2.1-1.8-1.5-1.2-0.9-0.6-0.300.30.60.91.21.51.82.12.4
    z-8-7-6-5-4-3-2-1012345678
    Table 2. Central coordinates of voxelunit: mm
    Zhian Wu, Xiaoyu Zhu, Jian Li, Biao Zhang, Chuanlong Xu. Volumetric-Calibration Ray Tracing-Based Calculation Method of Weight Coefficient in Light Field PIV[J]. Acta Optica Sinica, 2021, 41(20): 2010001
    Download Citation