• Photonic Sensors
  • Vol. 11, Issue 3, 305 (2021)
Surjeet RAIKWAR1, Y. K. PRAJAPATI2、*, D. K. SRIVASTAVA1, J. B. MAURYA1, and J. P. SAINI3
Author Affiliations
  • 1Department of Electronics and Communication Engineering, Bundelkhand Institute of Engineering and Technology, Jhansi 284128, Uttar Pradesh, India
  • 2Department of Electronics and Communication Engineering, Motilal Nehru National Institute of Technology Allahabad, Prayagraj 211004, Uttar Pradesh, India
  • 3Netaji Subhas University of Technology, Dwarka 110078, New Delhi, India
  • show less
    DOI: 10.1007/s13320-020-0587-0 Cite this Article
    Surjeet RAIKWAR, Y. K. PRAJAPATI, D. K. SRIVASTAVA, J. B. MAURYA, J. P. SAINI. Detection of Leptospirosis Bacteria in Rodent Urine by Surface Plasmon Resonance Sensor Using Graphene[J]. Photonic Sensors, 2021, 11(3): 305 Copy Citation Text show less
    References

    [1] P. N. Levett, “Leptospirosis,” Clinical Microbiology Reviews, 2001, 14(2): 296–326.

    [2] A. Packchanian, “Susceptibility and resistance of certain species of American deer mice, genus Peromyscus, and other rodents to Leptospira Icterohaemorrhagiae,” Public Health Reports (1896-1970), 1940, 55(31): 1389–1402.

    [3] S. Faine, B. Adler, C. Bolin, and P. Perolat, Leptospira and leptospirosis. Melbourne, Australia: MediSci, 1999

    [4] F. Costa, J. E. Hagan, J. Calcagno, M. Kane, P. Torgerson, M. S. Martinez-Silveira, et al., “Global morbidity and mortality of leptospirosis: a systematic review,” Plos Neglected Tropical Diseases, 2015, 9(9): e0003898.

    [5] S. N. Ahmed, S. Shah, and F. M. H. Ahmad, “Laboratory diagnosis of leptospirosis,” Journal of Postgraduate Medicine, 2005, 51(3): 195.

    [6] J. Homola, “Present and future of surface plasmon resonance biosensors,” Analytical and Bioanalytical Chemistry, 2003, 377(3): 528–539.

    [7] J. B. Maurya and Y. K. Prajapati, “Influence of dielectric coating on performance of surface plasmon resonance sensor,” Plasmonics, 2017, 12(4): 1121–1130.

    [8] E. Kretschmann and H. Raether, “Radiative decay of non radiative surface plasmons excited by light,” Zeitschrift für Naturforschung A, 1968, 23(12): 2135–2136.

    [9] B. Liedberg, C. Nylander, and I. Lundstrom, “Surface plasmon resonance for gas detection and biosensing,” Sensors and Actuators, 1983, 4: 299–304.

    [10] J. B. Maurya and Y. K. Prajapati, “A comparative study of different metal and prism in the surface plasmon resonance biosensor having MoS2-graphene,” Optical and Quantum Electronics, 2016, 48(5): 280.

    [11] L. Wu, H. S. Chu, W. S. Koh, and E. P. Li, “Highly sensitive graphene biosensors based on surface plasmon resonance,” Optics Express, 2010, 18(14): 14395–14400.

    [12] D. G. Papageorgiou, I. A. Kinloch, and R. J. Young, “Mechanical properties of graphene and graphene-based nanocomposites,” Progress in Materials Science, 2017, 90: 75–127.

    [13] G. B. McGaughey, M. Georgia, and A. K. Rappe, “π-stacking interactions alive and well in proteins,” Journal of Biological Chemistry, 1998, 273(25): 15458–15463.

    [14] B. Song, D. Li, W. Qi, M. Elstner, C. Fan, and H. Fang, “Graphene on Au (111): a highly conductive material with excellent adsorption properties for high-resolution bio/nanodetection and identification,” ChemPhysChem, 2010, 11(3): 585–589.

    [15] A. Upadhyay, Y. K. Prajapati, and R. Tripathi, “Analytical study of planar waveguide sensor with a metamaterial guiding layer,” Photonic Sensors, 2017, 7(4): 377–384.

    [16] S. X. Xia, X. Zhai, Y. Huang, J. Q. Liu, L. L. Wang, and S. C. Wen, “Graphene surface plasmons with dielectric metasurface,” Journal of Lightwave Technology, 2017, 35(20): 4553–4558.

    [17] S. X. Xia, X. Zhai, L. L. Wang, and S. C. Wen, “Plasmonically induced transparency in double-layered graphene nanoribbons,” Photonics Research, 2018, 6(7): 692–702.

    [18] L. Dieguez, N. Darwish, M. Mir, E. Martinez, M. Moreno, and J. Samitier, “Effect of the refractive index of buffer solutions in evanescent optical biosensors,” Sensor Letters, 2009, 7(5): 851–855.

    [19] R. J. Doyle and M. Rosenberg, Microbial cell surface hydrophobicity. Washington: American Society for Microbiology, 1990.

    [20] S. M. Notley, R. J. Crawford, and E. P. Ivanova, “Bacterial interaction with graphene particles and surfaces,” Electoral Studies, 2013, 25(2): 351–368.

    [21] R. Kumar, A. S. Kushwaha, M. Srivastava, H. Mishra, and S. K. Srivastava, “Enhancement in sensitivity of graphene-based zinc oxide assisted bimetallic surface plasmon resonance (SPR) biosensor,” Applied Physics A, 2018, 124(3): 235.

    [22] S. Pal, A. Verma, S. Raikwar, Y. K. Prajapati, and J. P. Saini, “Detection of DNA hybridization using graphene-coated black phosphorus surface plasmon resonance sensor,” Applied Physics A, 2018, 124(5): 394.

    [23] Y. F. Kitagawa, T. Takahashi, and H. Hayashi, “Relationship between the refractive index and specific gravity of the rat urine,” Experimental Animals, 1981, 30(3): 307–311.

    [24] P. K. Maharana, R. Jha, and S. Palei, “Sensitivity enhancement by air mediated graphene multilayer based surface plasmon resonance biosensor for near infrared,” Sensors and Actuators B: Chemical, 2014, 190: 494–501.

    [25] A. K. Sharma, R. Jha, and B. D. Gupta, “Fiber-optic sensors based on surface plasmon resonance: a comprehensive review,” IEEE Sensors Journal, 2007, 7(8): 1118–1129.

    [26] A. Shalabney and I. Abdulhalim, “Electromagnetic fields distribution in multilayer thin film structures and the origin of sensitivity enhancement in surface plasmon resonance sensors,” Sensors and Actuators A: Physical, 2010, 159(1): 24–32.

    [27] I. Pockrand, “Surface plasma oscillations at silver surfaces with thin transparent and absorbing coatings,” Surface Science, 1978, 72(3): 577–588.

    [28] A. Verma, A. Prakash, and R. Tripathi. “Sensitivity enhancement of surface plasmon resonance biosensor using graphene and air gap,” Optics Communications, 2015, 357: 106–112.

    [29] S. Pal, Y. K. Prajapati, and J. P. Saini, “Influence of graphene’s chemical potential on SPR biosensor using ZnO for DNA hybridization,” Optical Review, 2020, 27(1): 57–64.

    [30] J. B. Maurya, Y. K. Prajapati, V. Singh, and J. P. Saini, “Sensitivity enhancement of surface plasmon resonance sensor based on graphene–MoS2 hybrid structure with TiO2-SiO2 composite layer,” Applied Physics A, 2015, 121(2): 525–533.

    Surjeet RAIKWAR, Y. K. PRAJAPATI, D. K. SRIVASTAVA, J. B. MAURYA, J. P. SAINI. Detection of Leptospirosis Bacteria in Rodent Urine by Surface Plasmon Resonance Sensor Using Graphene[J]. Photonic Sensors, 2021, 11(3): 305
    Download Citation