• Chinese Optics Letters
  • Vol. 22, Issue 10, 101201 (2024)
Yeguang Yan1,2, Jixi Lu1,2,3,*, Kun Wang1,2, Fei Lu1,2..., Shaowen Zhang1,2, Ziao Liu1,2,3, Xiaoyu Li1,2,3 and Binquan Zhou1,2,3|Show fewer author(s)
Author Affiliations
  • 1Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
  • 2Zhejiang Provincial Key Laboratory of Ultra-Weak Magnetic-Field Space and Applied Technology, Hangzhou Innovation Institute, Beihang University, Hangzhou 310051, China
  • 3Hefei National Laboratory, Hefei 230088, China
  • show less
    DOI: 10.3788/COL202422.101201 Cite this Article Set citation alerts
    Yeguang Yan, Jixi Lu, Kun Wang, Fei Lu, Shaowen Zhang, Ziao Liu, Xiaoyu Li, Binquan Zhou, "High-sensitivity closed-loop three-axis atomic magnetometer using two elliptically polarized laser beams," Chin. Opt. Lett. 22, 101201 (2024) Copy Citation Text show less

    Abstract

    The high-sensitivity three-axis detection of magnetic fields is widely used in various applications. Our study demonstrates an atomic magnetometer detecting vector magnetic field, of which the core components are one glass cell and two elliptically polarized laser beams. The light-intensity noise is suppressed by differential detection technology, so a higher sensitivity is obtained compared with our previous work. The three-axis average sensitivities of the atomic magnetometer simultaneously reached 14 fT/Hz1/2 along the x axis, 11 fT/Hz1/2 along the y axis, and 25 fT/Hz1/2 along the z axis. Furthermore, the atomic magnetometer’s dynamic range was further improved to 150 nT, and its bandwidth was increased to over 200 Hz using a closed-loop control system. The proposed three-axis atomic magnetometer with a large dynamic range and a wide bandwidth holds great promise for biomagnetic measurement in a more challenging environment.
    dPdt=1q[γB×P+Rop(sz^P)RtotP],

    View in Article

    θ=12lrecnPzfD1vvD1(vvD1)2+(ΓD1/2)2,

    View in Article

    Pzα2sRopJ0(u)J1(u)(Rop+Rtot)2Bysin(ωmt),

    View in Article

    Gclosed(s)=KcoilG0(Kps+Ki)s2/ωc+(1+KcoilG0Kp)s+KcoilG0Ki,

    View in Article

    BLS=srecfD1ϕγvvD1(vvD1)2+(ΓD1/2)2,

    View in Article

    Yeguang Yan, Jixi Lu, Kun Wang, Fei Lu, Shaowen Zhang, Ziao Liu, Xiaoyu Li, Binquan Zhou, "High-sensitivity closed-loop three-axis atomic magnetometer using two elliptically polarized laser beams," Chin. Opt. Lett. 22, 101201 (2024)
    Download Citation