• High Power Laser and Particle Beams
  • Vol. 31, Issue 6, 63206 (2019)
Gao Yuan1、2、3, Qin Feng1、2、3, and Wu Shuang1、2、3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.11884/hplpb201931.190053 Cite this Article
    Gao Yuan, Qin Feng, Wu Shuang. Device for uniformity calibration of high-intensity electromagnetic pulse radiation[J]. High Power Laser and Particle Beams, 2019, 31(6): 63206 Copy Citation Text show less

    Abstract

    The uniformity of high-intensity electromagnetic radiation field is mainly realized by multiple tests at a single point presently, which will inevitably lead to measurement errors due to the time-varying characteristics of the radiation signal itself. Moreover, the method of multiple tests at a single point greatly increases the test time and lowers the test efficiency. To solve these problems, a device realizing multi-points test was designed. The test area can be adjusted automatically. The simulation results show that the device can meet the 9-point uniformity test of radiation field in the range of 500 mm×500 mm-1500 mm×1500 mm. In the 1000 mm×1000 mm test area, the experimental verification was carried out for the two frequency points of 1.35 GHz and 2.88 GHz. The experiment shows that the designed test device can meet the 9-point automatic test requirement of high-intensity radiation field uniformity, which greatly improves the test efficiency and automation.
    Gao Yuan, Qin Feng, Wu Shuang. Device for uniformity calibration of high-intensity electromagnetic pulse radiation[J]. High Power Laser and Particle Beams, 2019, 31(6): 63206
    Download Citation