• Laser & Optoelectronics Progress
  • Vol. 55, Issue 1, 11203 (2018)
Liu Luyao*, Huang Qiuhong, Liu Jiming, and Zhao Min
Author Affiliations
  • School of Mechanical and Precision Instrument Engineering, Xi''an University of Technology, Xi''an, Shaanxi 710048, China
  • show less
    DOI: 10.3788/LOP55.011203 Cite this Article Set citation alerts
    Liu Luyao, Huang Qiuhong, Liu Jiming, Zhao Min. Fast Adaptive Correlation Matching Barcode Location Method for Digital Level[J]. Laser & Optoelectronics Progress, 2018, 55(1): 11203 Copy Citation Text show less
    Diagram of digital level measurement system
    Fig. 1. Diagram of digital level measurement system
    Adaptive scaling shift-related matching barcode location principle
    Fig. 2. Adaptive scaling shift-related matching barcode location principle
    Schematic diagram of measurement reading
    Fig. 3. Schematic diagram of measurement reading
    Shift match correlation coefficient curves of (a) Leica and (b) Sokkia; comparison of one-dimensional gray curve of measured image and template image of (c) Leica and (d) Sokkia
    Fig. 4. Shift match correlation coefficient curves of (a) Leica and (b) Sokkia; comparison of one-dimensional gray curve of measured image and template image of (c) Leica and (d) Sokkia
    Number of measurement1234567
    Value of theory295.000322.250705.000832.250930.4001103.6001269.000
    Value of experiment294.876321.930704.684832.000930.0701103.2141268.705
    Value of difference0.1240.3200.3160.2500.3300.3860.295
    Table 1. Results of seven experimental measurements with Zeissmm
    Number of measurement1234567
    Value of theory258.500357.500427.500690.500817.5001300.0001530.000
    Value of experiment258.107357.335427.294690.178817.2391299.6001529.736
    Value of difference0.3930.1650.2060.3220.2610.4000.264
    Table 2. Results of seven experimental measurements with Topconmm
    Number of measurement1234567
    Value of theory273.750321.500528.250870.250993.0001207.2501438.250
    Value of experiment273.449321.171527.911869.947992.8341206.9701437.936
    Value of difference0.3010.3290.3390.3030.1660.2800.314
    Table 3. Results of seven experimental measurements with Sokkiamm
    Number of measurement1234567
    Value of theory264.800425.550570.000632.078683.250795.3401095.000
    Value of experiment264.563425.193569.730631.886682.903794.9761094.732
    Value of difference0.2370.3570.2700.1920.3470.3640.268
    Table 4. Results of seven experimental measurements with Leicamm
    Distance /mBarcode imageMatching timeTime /s
    LeicaSokkiaLeicaSokkiaLeicaSokkia
    83182922.5322.468
    153102852.6192.682
    252952732.8412.765
    Table 5. Measuring time and matching times of Leica and Sokkia under different distances
    Liu Luyao, Huang Qiuhong, Liu Jiming, Zhao Min. Fast Adaptive Correlation Matching Barcode Location Method for Digital Level[J]. Laser & Optoelectronics Progress, 2018, 55(1): 11203
    Download Citation