• Photonic Sensors
  • Vol. 12, Issue 1, 84 (2022)
Haibin CHEN1、2, Tianchong XIE1, Jiashuang FENG1, Xiongxing ZHANG1、2、*, Wei WANG1、2, Yanping LI1, and Zilong GUO1、2
Author Affiliations
  • 1School of Optoelectronic Engineering, Xi’an Technological University, Xi’an 710021, China
  • 2Shaanxi Province Key Lab of Photoelectric Measurement and Instrument Technology, Xi’an Technological University, Xi’an 710021, China
  • show less
    DOI: 10.1007/s13320-021-0625-6 Cite this Article
    Haibin CHEN, Tianchong XIE, Jiashuang FENG, Xiongxing ZHANG, Wei WANG, Yanping LI, Zilong GUO. A Miniature Fiber Tip Polystyrene Microsphere Temperature Sensor With High Sensitivity[J]. Photonic Sensors, 2022, 12(1): 84 Copy Citation Text show less
    References

    [1] K. S. Kim, J. W. Yoo, S. K. Kim, and B. Y. Kim, “Embedded intrinsic Fabry-Perot optical fiber sensors in the cement concrete structure for health monitoring system,” SPIE, 1996, 2718: 218–231.

    [2] B. Qi, G. R. Pickrell, P. Zhang, Y. Duan, W. Peng, J. C. Xu, et al., “Fiber optic pressure and temperature sensors for oil down hole application,” Fiber Optic Sensor Technology & Applications. International Society for Optics and Photonics, 2002, 4578: 182– 190.

    [3] K. A. Murphy, M. F. Gunther, A. M. Vengsarkar, and R. O. Claus, “Fabry-Perot fiber-optic sensors in fullscale fatigue testing on an F-15 aircraft,” Applied Optics, 1992, 31(4): 431–433.

    [4] G. Minas, J. C. Ribeiro, J. S. Martins, R. F. Wolffenbuttel, and J. H. Correia, “An array of Fabry- Perot optical-channels for biological fluids analysis,” Sensors & Actuators A Physical, 2004, 115(2–3): 362–367.

    [5] M. Jedrzejewska-Szczerska, “Response of a new low-coherence Fabry-Perot sensor to Hematocrit levels in human blood,” Sensors, 2014, 14(4): 6965–6976.

    [6] J. Ma, W. Jin, H. L. Ho, and J. Y. Dai, “Highsensitivity fiber-tip pressure sensor with graphene diaphragm,” Optics Letters, 2012, 37(13): 2493– 2495.

    [7] D. Donlagic and E. Cibula, “All-fiber highsensitivity pressure sensor with SiO2 diaphragm,” Optics Letters, 2005, 30(16): 2071–2073.

    [8] F. Guo, T. Fink, M. Han, L. Koester, J. Turner, and J. Huang, “High-sensitivity, high-frequency extrinsic Fabry- Perot interferometric fiber-tip sensor based on a thin silver diaphragm,” Optics Letters, 2012, 37(9): 1505–1507.

    [9] Z. Zhang, C. Liao, J. Tang, Z. Bai, K. Guo, M. Hou, et al., “High-sensitivity gas-pressure sensor based on fiber-tip PVC diaphragm Fabry-Pérot interferometer,” Journal of Lightwave Technology, 2017, 35(18): 4067–4071.

    [10] X. Qi, S. Wang, J. Jiang, K. Liu, X. Wang, Y. Yang, et al., “Fiber optic Fabry-Perot pressure sensor with embedded MEMS micro-cavity for ultra-high pressure detection,” Journal of Lightwave Technology, 2019, 37(11): 2719– 2725.

    [11] M. Li, M. Wang, and H. Li, “Optical MEMS pressure sensor based on Fabry-Perot interferometry,” Optics Express, 2006, 14(4): 1497–1504.

    [12] Y. Zhang, L. Yuan, X. Lan, A. Kaur, J. Huang, and H. Xiao, “High-temperature fiber-optic Fabry-Perot interferometric pressure sensor fabricated by femtosecond laser,” Optics Letters, 2013, 38(22): 4609–4612.

    [13] J. Liu, L. Yuan, J. Lei, W. Zhu, B Cheng, Q. Zhang, et al., “Micro-cantilever-based fiber optic hydrophone fabricated by a femtosecond laser,” Optics Letters, 2017, 42(13): 2459–2462.

    [14] C. Liao, S. Liu, L. Xu, C. Wang, Y. Wang, Z. Li, et al., “Sub-micron silica diaphragm-based fiber-tip Fabry-Perot interferometer for pressure measurement,” Optics Letters, 2014, 39(10): 2827–2830.

    [15] J. Ma, J. Ju, L. Jin, and W. Jin, “A compact fiber-yip micro-cavity sensor for high-pressure measurement,” IEEE Photonics Technology Letters, 2011, 23(21): 1561–1563.

    [16] J. Ma, W. Jin, and L. Jin, “A novel fiber-tip microcavity sensor for high temperature application,” in 21st International Conference on Optical Fiber Sensors, Ottawa, 2011, 7753: 775312.

    [17] W. Chen, D. Wang, B. Xu, Z. Wang, and C. Zhao, “Fabry-Perot interferometer fiber tip sensor based on a glass microsphere glued at the etched end of multimode fiber,” Optical Engineering, 2017, 56(5): 057107.

    [18] X. Jiang, D. Chen, J. Shao, G. Feng, and J. Yang, “Low-cost fiber-tip Fabry-Perot interferometer and its application for high temperature sensing,” Chinese Optics Letters, 2014, 12(s1): S10609.

    [19] X. Tan, X. Li, Y. Geng, Z. Yin, L. Wang, W. Wang, et al., “Polymer microbubble-based Fabry-Perot fiber interferometer and sensing applications,” IEEE Photonics Technology Letters, 2015, 27(19): 2035– 2038.

    [20] D. Duan, Y. Rao, Y. S. Hou, and T. Zhu, “Microbubble based fiber-optic Fabry-Perot interferometer formed by fusion splicing single-mode fibers for strain measurement,” Applied Optics, 2012, 51(8): 1033– 1036.

    [21] J. Song and M. Winnik, “Cross-linked, monodisperse, micron-sized polystyrene particles by two-stage dispersion polymerization,” Macromolecules, 2005, 38(20): 8300–8307.

    Haibin CHEN, Tianchong XIE, Jiashuang FENG, Xiongxing ZHANG, Wei WANG, Yanping LI, Zilong GUO. A Miniature Fiber Tip Polystyrene Microsphere Temperature Sensor With High Sensitivity[J]. Photonic Sensors, 2022, 12(1): 84
    Download Citation