    Zhijing Yu, Jianwen Zheng, Yongkui Tao, Jun Wu. Three-Point Light Pen Measurement Method Based on Light Field Imaging[J]. Laser & Optoelectronics Progress, 2020, 57(3): 032001 Copy Citation Text show less
    Flow chart of measurement system
    Fig. 1. Flow chart of measurement system
    Diagram of P3P projection
    Fig. 2. Diagram of P3P projection
    Diagram of principle of light field imaging
    Fig. 3. Diagram of principle of light field imaging
    Digital refocusing
    Fig. 4. Digital refocusing
    Light field images of all windows
    Fig. 5. Light field images of all windows
    Light field image of local window
    Fig. 6. Light field image of local window
    Contrast measurement system
    Fig. 7. Contrast measurement system
    Design of light pen
    Fig. 8. Design of light pen
    Local four-dimensional light field
    Fig. 9. Local four-dimensional light field
    Internal parameterCalibration value
    c /mm22.441
    fc /mm(1296.24851,1296.28441)
    cc /mm(311.53056,223.32054)
    kc /mm(-0.29994,0.78014,0.00012,-0.00133,0.00000)
    err /pixel(0.05143,0.05310)
    Table 1. Calibration results
    Reference data of translation stage50100150200
    MeasurementresultsMaximum50.336100.546150.428200.215
    Minimum49.536100.131150.224199.343
    Average value50.250100.346150.334199.655
    Correct rate (compared with reprojection results)TrueTrueTrueTrue
    Table 2. Results of contrast experiments along X-axis directionmm
    Reference data of translation stage50100150200
    MeasurementresultsMaximum50.426100.525150.328200.316
    Minimum50.224100.136149.860200.024
    Average value50.336100.395150.157200.254
    Correct rate (compared with reprojection results)TrueTrueTrueTrue
    Table 3. Results of contrast experiments along Y-axis directionmm
    Reference data of translation stage50100150200
    MeasurementresultsMaximum50.725100.634150.536200.465
    Minimum49.982100.152149.826200.036
    Average value50.535100.462150.235200.240
    Correct rate (compared with reprojection results)TrueTrueTrueTrue
    Table 4. Results of contrast experiments along Z-axis directionmm