• Acta Optica Sinica
  • Vol. 42, Issue 16, 1611002 (2022)
Mingjuan Liao1、2, Lei Li2, Xiaojiao Duan1、2、3, Dabing Chen4, and Fenglin Liu1、2、3、*
Author Affiliations
  • 1Key Laboratory of Optoelectronic Technology & Systems, Ministry of Education, Chongqing University,Chongqing 400044, China
  • 2Industrial CT Non-Destructive Testing Engineering Research Center, Ministry of Education, Chongqing University, Chongqing 400044, China
  • 3Chongqing Zhence Science and Technology Co., Ltd., Chongqing 401332, China
  • 4Research Institute, State Grid Jiangsu Electric Power Co., Ltd., Nanjing 211103, Jiangsu , China
  • show less
    DOI: 10.3788/AOS202242.1611002 Cite this Article Set citation alerts
    Mingjuan Liao, Lei Li, Xiaojiao Duan, Dabing Chen, Fenglin Liu. Local Source-Translation CT Imaging for Testing In-Service High-Voltage Cables[J]. Acta Optica Sinica, 2022, 42(16): 1611002 Copy Citation Text show less
    References

    [1] Meng Z Z, Li X, Yu Y et al. Review on the research status of the high voltage XLPE cable buffer layer failure[J]. Electric Power, 54, 33-41, 55(2021).

    [2] Li W J, Ouyang B H, Song P X et al. Analysis and experimental study on erosion failure of cushion layer of power cable[J]. Synthetic Materials Aging and Application, 50, 38-41(2021).

    [3] Huang Y, Yin Y, Wu C S. Study on electrical properties of water blocking buffer layer in high voltage cables[J]. Wire & Cable, 6-9, 19(2018).

    [4] Muharam R, Lestariningsih I, Nurlely et al. Designing phantom in-house for quick check computed radiography (CR) and digital radiography (DR) system[J]. Journal of Physics: Conference Series, 1568, 012023(2020).

    [5] de Chiffre L, Carmignato S, Kruth J P et al. Industrial applications of computed tomography[J]. CIRP Annals, 63, 655-677(2014).

    [6] Lü H Y, Zou J, Zhao J T et al. Review on development of nano-computed tomography imaging technology[J]. Laser & Optoelectronics Progress, 57, 140001(2020).

    [7] Pi Z Z, Yu H J, Li L et al. Triple-source swinging spiral CT imaging method for security inspection[J]. Acta Optica Sinica, 41, 1611003(2021).

    [8] Liu S W, Duan X L, Li G et al. Research on digital X-ray non-destructive testing technology of cable buffer layer defects[J]. Hunan Electric Power, 40, 18-21(2020).

    [9] Su C Q. Failure analysis of three 230 kV XLPE cables[C], 22-25(2010).

    [10] Tian Z J, Yu H J, Wang L B et al. Orthogonal translation computed laminography[J]. Acta Optica Sinica, 40, 2211002(2020).

    [11] Li L, Tan C D, Liao M J et al. Analytic reconstruction for parallel translational computed tomography based on radon inverse transform[J]. Acta Optica Sinica, 41, 0611003(2021).

    [12] Schön T, Fuchs T, Hanke R et al. A translation-based data acquisition method for computed tomography: theoretical analysis and simulation study[J]. Medical Physics, 40, 081922(2013).

    [13] Gao H W, Zhang L, Chen Z Q et al. Straight-line-trajectory-based X-ray tomographic imaging for security inspections: system design, image reconstruction and preliminary results[J]. IEEE Transactions on Nuclear Science, 60, 3955-3968(2013).

    [14] Liu B D, Zeng L. Parallel SART algorithm of linear scan cone-beam CT for fixed pipeline[J]. Journal of X-Ray Science and Technology, 17, 221-232(2009).

    [15] Yu H J, Li L, Tan C D et al. X-ray source translation based computed tomography (STCT)[J]. Optics Express, 29, 19743-19758(2021).

    [16] Chetih N, Messali Z. Tomographic image reconstruction using filtered back projection (FBP) and algebraic reconstruction technique (ART)[C], 15418482(2015).

    [17] Jiang M, Wang G. Convergence of the simultaneous algebraic reconstruction technique (SART)[J]. IEEE Transactions on Image Processing, 12, 957-961(2003).

    [18] Wu W W, Quan C, Liu F L. Filtered back-projection image reconstruction algorithm for opposite parallel linear CT scanning[J]. Acta Optica Sinica, 36, 0911009(2016).

    [19] Kong H H, Yu H Y. Analytic reconstruction approach for parallel translational computed tomography[J]. Journal of X-Ray Science and Technology, 23, 213-228(2015).

    [20] Gao H W, Zhang L, Xing Y X et al. Volumetric imaging from a multisegment straight-line trajectory and a practical reconstruction algorithm[J]. Optical Engineering, 46, 077004(2007).

    [21] Xu J Q, Zhao Y S, Li H W et al. An image reconstruction model regularized by edge-preserving diffusion and smoothing for limited-angle computed tomography[J]. Inverse Problems, 35, 085004(2019).

    [22] Quinto E T. Artifacts and visible singularities in limited data X-ray tomography[J]. Sensing and Imaging, 18, 1-14(2017).

    [23] Yan B, Han Y, Wei F et al. Review of algorithms for over FOV size object in cone-beam CT[J]. Computerized Tomography Theory and Applications, 22, 373-384(2013).

    [24] Mitsuya Y. Compressed sensing-based reconstruction for computed tomography with translational trajectory[J]. Inverse Problems in Science and Engineering, 28, 497-512(2020).

    [25] Wang G, Schweiger G D, Vannier M W. An iterative algorithm for X-ray CT fluoroscopy[J]. IEEE Transactions on Medical Imaging, 17, 853-856(1998).

    [26] van Aarle W, Palenstijn W J, Cant J et al. Fast and flexible X-ray tomography using the ASTRA toolbox[J]. Optics Express, 24, 25129-25147(2016).

    [27] Huang L Y, Zhu S P, Kuang T[M]. Simulation experiment of medical image reconstruction(2015).

    Mingjuan Liao, Lei Li, Xiaojiao Duan, Dabing Chen, Fenglin Liu. Local Source-Translation CT Imaging for Testing In-Service High-Voltage Cables[J]. Acta Optica Sinica, 2022, 42(16): 1611002
    Download Citation