    Yuefeng Qi, Cui Jia, Lei Liu, Jin Zhang, Yanyan Liu, Wei Wang. Biosensing Properties of Nanofilm-Modified Long-Period Fiber Gratings[J]. Acta Optica Sinica, 2018, 38(10): 1006005 Copy Citation Text show less
    Effects of the changes in the refractive index of the grating surface on the LPFG resonance peak
    Fig. 1. Effects of the changes in the refractive index of the grating surface on the LPFG resonance peak
    Antigen-antibody reaction curve
    Fig. 2. Antigen-antibody reaction curve
    Schematic of the nanofilm-modified LPFG biosensor
    Fig. 3. Schematic of the nanofilm-modified LPFG biosensor
    Fabrication of the sensitive film. (a) Surface modified with sulfuric acid; (b) surface modified with APTES; (c) surface modified with glutaric dialdehyde; (d) immobilization of the identifying biomolecules
    Fig. 4. Fabrication of the sensitive film. (a) Surface modified with sulfuric acid; (b) surface modified with APTES; (c) surface modified with glutaric dialdehyde; (d) immobilization of the identifying biomolecules
    Microscopic images. (a) Grating area before the experiment; (b) nanofilm-modified LPFG biosensing area after the immunoassay
    Fig. 5. Microscopic images. (a) Grating area before the experiment; (b) nanofilm-modified LPFG biosensing area after the immunoassay
    Effects of the pre-chemical treatments on the resonance peak of LPFG
    Fig. 6. Effects of the pre-chemical treatments on the resonance peak of LPFG
    Effects of the immunoassay on the resonance peak of LPFG at Λ=445 μm. (a) Concentration of rabbit IgG with 0.0025-0.0075 mg·mL-1; (b) concentration of rabbit IgG with 0.0075-0.0300 mg·mL-1
    Fig. 7. Effects of the immunoassay on the resonance peak of LPFG at Λ=445 μm. (a) Concentration of rabbit IgG with 0.0025-0.0075 mg·mL-1; (b) concentration of rabbit IgG with 0.0075-0.0300 mg·mL-1
    Peak loss of LPFG at Λ=445 μm with different rabbit IgG concentrations
    Fig. 8. Peak loss of LPFG at Λ=445 μm with different rabbit IgG concentrations
    Peak loss of LPFG with different rabbit IgG concentrations. (a) Λ = 460 μm; (b) Λ = 500 μm
    Fig. 9. Peak loss of LPFG with different rabbit IgG concentrations. (a) Λ = 460 μm; (b) Λ = 500 μm
    Serial numberWavelength /μm
    445460500
    10.00250.00031250.00125
    20.00500.00062500.00250
    30.00750.00125000.00375
    40.01000.00250000.00500
    50.01250.00500000.00625
    60.01500.01000000.00750
    70.01750.02000000.00875
    80.02000.04000000.01000
    90.02250.05000000.01125
    100.02500.05500000.01250
    110.03000.06500000.01375
    Table 1. Rabbit IgG concentrations corresponding to different period gratings