• Opto-Electronic Engineering
  • Vol. 37, Issue 1, 13 (2010)
[in Chinese]*, [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3969/j.issn.1003-501x.2010.01.03 Cite this Article
    [in Chinese], [in Chinese], [in Chinese]. Using Dilating Gabor Transform to Fringe Analysis in Distortion Measurement[J]. Opto-Electronic Engineering, 2010, 37(1): 13 Copy Citation Text show less
    References

    [1] Rahul Swaminathan,Shree K. Nayar. Non-metric calibration of wide-angle lenses and polycameras [J]. IEEE Transactions on Pattern Analysis and Machine Intelligence(S0162-8828),2000,22(10):1172-1178.

    [2] Frédéric Devernay,Olivier Faugeras. Straight lines have to be straight:automatic calibration and removal of distortion from scenes of structured environments [J]. Machine Vision and Applications(S0932-8092),2001,13(1):14-24.

    [3] Juyang Weng,Paul Cohen,Marc Herniou. Camera Calibration with Distortion Models and Accuracy Evaluation [J]. IEEE Transactions on Pattern Analysis and Machine Intelligence,1992,14(10):965-980.

    [4] NIU Jian-jun,LIU Shang-qiang,YAO Rong-hui,et al. Algorithm for image correction in high precision imaging measurement system [J]. Acta Phonica Sinica,2006,35(9):1317-1819.

    [5] ZHANG Hong-tao,DUAN Fa-jie,WANG Xue-ying,et al. Vision model calibration based on grid target [J]. Opto-Electronic Engingeering,2006,33(11):57-60.

    [6] XING Mai-lin,LIU Jian-ping,LIN Jia-ming,et al. Distortion measurement of CCD camera with a large-field short focal length lens [J]. Optical Technique,2003,29(3):377-379.

    [7] LIN Jia-min,XING Mai-ling,SHA Din-guo,et al. Distortion measurement of CCD imaging system with short focal length and large-field objective [J]. Optics and Lasers in Engineering(S0143-8166),2005,43(10):1137-1144.

    [8] YU Jun,LIN Jia-ming,YANG Jian-yu,et al. Distortion measurement and calibration technology for CCD camera system on New Target board [J]. Acta Optica Sinica,2007,27(8):1440-1442.

    [9] WANG Zhan-bin,ZHAO Hui,TAO Wei,et al. Barrel distortion correction of wide-angle lens based on spline function [J]. Opto-Electronic Engingeering,2008,35(4):140-144.

    [10] ZHONG Jin-gang,WENG Jia-wen. Dilating Gabor transform for the fringe analysis of 3-D shape measurement [J]. Opt. Eng(S0091-3286),2004,43(4):895-899.

    [11] Mitsuo Takeda,Kazuhiro Mutoh. Fourier Transform Profilometry for the Automatic Measurement of 3-D Object Shapes [J]. Appl. Opt(S2040-8978),1983,22(24):3977-3982.

    CLP Journals

    [1] LIN Hong-bin, LIU Bin, ZHANG Yu-cun. Self-calibration of Single Camera System Used in Cylinder-shaped Forging Parts Measurement[J]. Opto-Electronic Engineering, 2012, 39(3): 46

    [2] Weishuai Zhou, Jiawen Weng, Junzheng Peng, Jingang Zhong. Wide-angle lenses distortion calibration using phase demodulation of phase-shifting fringe-patterns[J]. Infrared and Laser Engineering, 2020, 49(6): 20200039

    [in Chinese], [in Chinese], [in Chinese]. Using Dilating Gabor Transform to Fringe Analysis in Distortion Measurement[J]. Opto-Electronic Engineering, 2010, 37(1): 13
    Download Citation