• Infrared and Laser Engineering
  • Vol. 48, Issue 8, 813003 (2019)
Zhao Xianyu1、2、*, Xue Donglin1, and Cheng Qiang1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/irla201948.0813003 Cite this Article
    Zhao Xianyu, Xue Donglin, Cheng Qiang. Research on Hartmann principle based on sub-aperture slope scanning detection and error[J]. Infrared and Laser Engineering, 2019, 48(8): 813003 Copy Citation Text show less
    References

    [1] Wang Jianli, Chen Tao, Zhang Jingxu, et al. General requirements and key technologies for the ground- based high resolution EO imaging telescope [J]. Opt Precision Eng, 2008, 16(5): 1-16. (in Chinese)

    [2] Li Hongzhuang, Wang Zhichen, Wang Fuguo, et al.Method of wavefront error test in the outfield for large aperture telescope [J]. Acta Photonica Sinica, 2012, 41(1): 39-42. (in Chinese)

    [3] Yang Fei, Ming Ming, Chen Baogang, et al. Influence of diversification of elevation to the opto-mechanical system of 1.23m telescope [J]. Laser & Optoelectronics Progress, 2012, 49(1): 39-42. (in Chinese)

    [4] Malacara D. Optical Shop Testing[M]. 3rd ed, US:John Wiley & Sons Inc, 2012.

    [5] Bell R M, Robins G C, Eugeni C, et al. LOTIS at completion of collimator integration[C]//SPIE, 2008,7107: 7017D.

    [6] Yan Lisong. Reaserch on algorithm test optical mirror by subapture stitching interferometry[D]. Beijing:University of Chinese Academy of Sciences, 2015. (in Chinese)

    [7] Yan Gongjing, Zhang Xianzhong. Technology of subaperture stitching testing optical convex spherical mirror [J]. Infrared and Laser Engineering, 2016, 45(5): 0517002. (in Chinese)

    [8] Feinberg L D, Hagopian J G, Diaz C. New approach to cryogenic optical testing the JWST[C]//SPIE, 2006, 6265: 23.

    [9] Feinberg L D, Barto A, Waldman M, et al. James webb space telescope system cryogenic optical test plans [C]//SPIE, 2011, 8150: 815007.

    [10] Malacara-Hernandez D, Malacara-Doblado D. What is a Hartmann test[J]. Applied Optics, 2015, 54: 2296-2301.

    [11] Qi Erhui, Luo Xiao, Li Ming, et al. Error analysis of scanning pentaprism system in optical testing on large aperture flat mirror[J]. Infrared and Laser Engineering,2015, 44(2): 639-646. (in Chinese)

    [12] Knight J S, Feinberg L, Howard J, et al. Hartmann test for the james webb space telescope[C]//SPIE, 2016, 9904: 99040C.

    Zhao Xianyu, Xue Donglin, Cheng Qiang. Research on Hartmann principle based on sub-aperture slope scanning detection and error[J]. Infrared and Laser Engineering, 2019, 48(8): 813003
    Download Citation