• Chinese Optics Letters
  • Vol. 13, Issue 10, 101101 (2015)
De Cai, Zhongfei Li, and Sung-Liang Chen*
Author Affiliations
  • University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University, Shanghai 200240, China
  • show less
    DOI: 10.3788/COL201513.101101 Cite this Article Set citation alerts
    De Cai, Zhongfei Li, Sung-Liang Chen. Photoacoustic microscopy by scanning mirror-based synthetic aperture focusing technique[J]. Chinese Optics Letters, 2015, 13(10): 101101 Copy Citation Text show less
    References

    [1] L. V. Wang. Nat. Photon., 3, 503(2009).

    [2] V. Ntziachristos. Nat. Methods, 7, 603(2010).

    [3] W. Song, Q. Wei, R. Zhang, H. Zhang. Chin. Opt. Lett., 12, 051704(2014).

    [4] K. Maslov, H. F. Zhang, S. Hu, L. V. Wang. Opt. Lett., 33, 929(2008).

    [5] S.-L. Chen, Z. Xie, L. J. Guo, X. Wang. Photoacoustics, 1, 30(2013).

    [6] H. F. Zhang, K. Maslov, G. Stoica, L. V. Wang. Nat. Biotechnol., 24, 848(2006).

    [7] H. F. Zhang, K. Maslov, L. V. Wang. Nat. Protoc., 2, 797(2007).

    [8] K. H. Song, E. W. Stein, J. A. Margenthaler, L. V. Wang. J. Biomed. Opt., 13, 054033(2008).

    [9] R. Ma, S. Söntges, S. Shoham, V. Ntziachristos, D. Razansky. Biomed. Opt. Express, 3, 1724(2012).

    [10] Z. Wu, M. Sun, Q. Wang, T. Liu, N. Feng, J. Liu, Y. Shen. Chin. Opt. Lett., 12, 121701(2014).

    [11] C. Frazier, W. O’Brien. IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 45, 196(1998).

    [12] M.-L. Li, W.-J. Guan, P.-C. Li. IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 51, 63(2004).

    [13] C.-K. Liao, M.-L. Li, P.-C. Li. Opt. Lett., 29, 2506(2004).

    [14] M.-L. Li, H. F. Zhang, K. Maslov, G. Stoica, L. V. Wang. Opt. Lett., 31, 474(2006).

    [15] S. Park, A. B. Karpiouk, S. R. Aglyamov, S. Y. Emelianov. Opt. Lett., 33, 1291(2008).

    [16] Z. Deng, X. Yang, H. Gong, Q. Luo. J. Appl. Phys., 109, 104701(2011).

    [17] Z. Deng, X. Yang, H. Gong, Q. Luo. Opt. Express, 20, 7555(2012).

    [18] J. Turner, H. Estrada, M. Kneipp, D. Razansky. Opt. Lett., 39, 3390(2014).

    [19] H. Estrada, J. Turner, M. Kneipp, D. Razansky. Laser Phys. Lett., 11, 045601(2014).

    [20] X. Jia, S. Yang. Eur. Phys. J.-Appl. Phys., 52, 30901(2010).

    [21] D. A. Nedosekin, M. Sarimollaoglu, E. V. Shashkov, E. I. Galanzha, V. P. Zharov. Opt. Express, 18, 8605(2010).

    [22] B.-Y. Hsieh, S.-L. Chen, T. Ling, L. J. Guo, P.-C. Li. Opt. Express, 20, 1588(2012).

    [23] T. J. Allen, E. Zhang, P. C. Beard. Proc. SPIE, 9323, 93230Z(2015).

    [24] J. Gateau, T. Chaigne, O. Katz, S. Gigan, E. Bossy. Opt. Lett., 38, 5188(2013).

    [25] Y. Zhou, G. Li, L. Zhu, C. Li, L. A. Cornelius, L. V. Wang. J. Biophoton.(2015).

    CLP Journals

    [1] Jizhou Zhang, Tingfa Xu, Xing Wang, Sining Chen, Guoqiang Ni. Fast gradational reconstruction for Fourier ptychographic microscopy[J]. Chinese Optics Letters, 2017, 15(11): 111702

    [2] Lin Li, Qian Li, Cuixia Dai, Qingliang Zhao, Tianhao Yu, Xinyu Chai, Chuanqing Zhou. Automated segmentation and quantitative study of retinal pigment epithelium cells for photoacoustic microscopy imaging[J]. Chinese Optics Letters, 2017, 15(5): 051101

    Data from CrossRef

    [5] Xiangwei Lin, Jaesok Yu, Naizhang Feng, Mingjian Sun. Synthetic aperture-based linear-array photoacoustic tomography considering the aperture orientation effect. Journal of Innovative Optical Health Sciences, 11, 1850015(2018).

    De Cai, Zhongfei Li, Sung-Liang Chen. Photoacoustic microscopy by scanning mirror-based synthetic aperture focusing technique[J]. Chinese Optics Letters, 2015, 13(10): 101101
    Download Citation