• Acta Optica Sinica
  • Vol. 37, Issue 10, 1034001 (2017)
Baolei Li*, Pingyu Zhang, Bin Li, Yang Mo, Bo Meng, and Yaojun Zhang
Author Affiliations
  • Security Inspection Division, First Research Institute of the Ministry of Public Security of PRC, Beijing 100048, China
  • show less
    DOI: 10.3788/AOS201737.1034001 Cite this Article Set citation alerts
    Baolei Li, Pingyu Zhang, Bin Li, Yang Mo, Bo Meng, Yaojun Zhang. Optimized Iterative Method for Projection Decomposition of X-Ray Dual-Energy Computed Tomography[J]. Acta Optica Sinica, 2017, 37(10): 1034001 Copy Citation Text show less
    Schematic of initial value selection for iterative calculation
    Fig. 1. Schematic of initial value selection for iterative calculation
    Spectra of true dual-energy CT system. (a) Low energy spectrum; (b) high energy spectrum
    Fig. 2. Spectra of true dual-energy CT system. (a) Low energy spectrum; (b) high energy spectrum
    Projection lookup table images of true dual-energy CT system. (a)(b) Before optimization; (c)(d) after optimization
    Fig. 3. Projection lookup table images of true dual-energy CT system. (a)(b) Before optimization; (c)(d) after optimization
    Spectra of pseudo dual-energy CT system. (a) Low energy spectrum; (b) high energy spectrum
    Fig. 4. Spectra of pseudo dual-energy CT system. (a) Low energy spectrum; (b) high energy spectrum
    Projection lookup table images of pseudo dual-energy CT system. (a) Carbon; (b) aluminum
    Fig. 5. Projection lookup table images of pseudo dual-energy CT system. (a) Carbon; (b) aluminum
    Gray scale curves of projection lookup tables of pseudo dual-energy CT system. (a) Carbon; (b) aluminum
    Fig. 6. Gray scale curves of projection lookup tables of pseudo dual-energy CT system. (a) Carbon; (b) aluminum
    Schematic of calibration scope optimization for dual-energy projection
    Fig. 7. Schematic of calibration scope optimization for dual-energy projection
    Linear attenuation coefficient curves of iron and copper
    Fig. 8. Linear attenuation coefficient curves of iron and copper
    True dual-energy projection curves of iron and copper
    Fig. 9. True dual-energy projection curves of iron and copper
    True dual-energy projection curves of copper
    Fig. 10. True dual-energy projection curves of copper
    Projection lookup table images of true dual-energy CT system after calibration scope optimization. (a) Carbon; (b) aluminum
    Fig. 11. Projection lookup table images of true dual-energy CT system after calibration scope optimization. (a) Carbon; (b) aluminum
    Pseudo dual-energy projection curve of copper
    Fig. 12. Pseudo dual-energy projection curve of copper
    Projection lookup table images of pseudo dual-energy CT system after calibration scope optimization. (a) Carbon; (b) aluminum
    Fig. 13. Projection lookup table images of pseudo dual-energy CT system after calibration scope optimization. (a) Carbon; (b) aluminum
    Baolei Li, Pingyu Zhang, Bin Li, Yang Mo, Bo Meng, Yaojun Zhang. Optimized Iterative Method for Projection Decomposition of X-Ray Dual-Energy Computed Tomography[J]. Acta Optica Sinica, 2017, 37(10): 1034001
    Download Citation