• Optics and Precision Engineering
  • Vol. 19, Issue 12, 2870 (2011)
QI Xiang-dong1,*, HAN Peng-peng1, PAN Ming-zhong1, and CUI Ji-cheng1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/ope.20111912.2870 Cite this Article
    QI Xiang-dong, HAN Peng-peng, PAN Ming-zhong, CUI Ji-cheng. Spectral calibration of imaging spectrometer with convex grating[J]. Optics and Precision Engineering, 2011, 19(12): 2870 Copy Citation Text show less
    References

    [1] OFFNER A. New concepts in projection mask aligners [J].Opt. Eng., 1975, 14:130-132.

    [2] REININGER F.VIRTIS: visible infrared thermal imaging spectrometer for the Rosetta mission [J]. SPIE, 1996, 2819:66-77.

    [3] LOBB D R. Imaging spectrometers using concentric optics [J]. SPIE, 1997, 3118:339-347.

    [4] BROWN T J, CORBETT F J, SPERA T J, et al.. Thermal infrared pushbroom imagery acquisition and processing[J]. SPIE, 1981, 304:37-56.

    [5] DINER D J, BRUEGGE C J, MARTONCHIK J V, et al..MISR: a multiangle imaging spectroradiometer for geophysical and climatological research [J]. IEEE Trans. Geosci. Remote Sens., 1989, 27:200-214.

    [6] SAINTPE O, DONNADIEU O, DAVANCENS R, et al..Development of a 2-D array for 1 to 2.35 mm hyperspectral imager [J]. SPIE, 1997, 2816:138-149.

    [7] ZHENG Y Q, WANG H, WANG Y F.Selection and design of systems for spaceborne hyperspectral imager [J]. Opt. Precision Eng., 2009, 17(11):2629-2637.(in Chinese)

    [8] DAVIS C O, KAPPUS M E, BOWLES J H, et al..Calibration, characterization, and first results with the Ocean PHILIS hyperspectral imager [J]. SPIE, 1999, 3753:160-168.

    [9] FOLKMAN M A, PEARI M J, LIAO I B, et al..EO-1/Hyperion hyperspectral imager design, development, characterization and calibration [J]. SPIE, 2001, 4151:40-51.

    [10] WIISON T H, DAVIS C O. Hyperspectral remote sensing technology(HRST) program and the Naval Earth Map Observer(NEM) satellite[J]. SPIE, 1998, 3437:2-11.

    [11] FIETCHER P A. Image acquisition planning for the CHRIS sensor onboard PROBA [J]. SPIE, 2004, 5546:141-150.

    [12] THOMAS G C, ROBERT O G, MICHAEL L. Accuracy of the spectral and radiometric laboratory calibration of the airborne visible/infrared imaging spectrometer(AVIRIS)[J]. SPIE, 1990, 1298:37-49.

    [13] AMOLD G T, FITZGERALD M F, GRANT P S, et al.. MODIS airborne simulator radiometric calibration[J]. SPIE, 1996, 2820:56-66.

    [14] LUSHALAN L, PETER J, DARREL G, et al.. Performance characterization of the hyperion imaging spectrometer instrument[J]. SPIE, 2004, 4135:264-275.

    [15] JERRY Z, DANIEL G, ROBERT M, et al.. Calibration procedures and measurements for the COMPASS hyperspectral imager[J]. SPIE, 2004, 5425:182-188.

    [16] YANG Y. Spectral calibration of hyperspectral imager[J].Infrared, 2006, 27(8):24-26.(in Chinese)

    [17] SHU R, XUE Y Q, YANG Y D. Calibration and application of airborne pushbroom Hyperspectral imager(PHI)[J]. SPIE, 2004, 5234:668-675.

    [18] PAN M ZH, QI X Y, XIAO G H, Design of the compact ground radiometer[J]. Infrared, 2010, 31(1):1-7.(in Chinese)

    [19] WANG J Y. Spectral response and spectral resolution of hyperspectral imager[J]. Imaging spectrum, 1991:44-50.(in Chinese)

    [20] WANG J Y. Analysis of the spectral resolution of hyperspectral imager[J]. Infrared, 1990, 9(4):277-286.(in Chinese)

    CLP Journals

    [1] CUI Ji-cheng, TANG Yu-guo, HAN Peng-peng, PAN Ming-zhong, ZHANG Jin-nan. Development of diagnostic imaging spectrometer for tumor on-line operation[J]. Optics and Precision Engineering, 2013, 21(12): 3043

    [2] XIA Zhi-wei, WANG Kai, FANG Wei, Wang Yu-peng. Applications and development of radiation calibration in orbit based on space monochromator[J]. Optics and Precision Engineering, 2015, 23(7): 1880

    [3] QIU Yan-qing, ZHANG Liu-liu, CHEN Miao-gen, WANG Cheng-qun. Photoelectric parameter measurement system for chip-on-board wafer level packaging LEDs[J]. Optics and Precision Engineering, 2016, 24(1): 39

    [4] ZHAO Min-jie, SI Fu-qi, JIANG Yu, ZHOU Hai-jin, WANG Shi-mei, LIU Wen-qing. In-lab calibration of space-borne differential optical absorption spectrometer[J]. Optics and Precision Engineering, 2013, 21(3): 567

    [5] [in Chinese], [in Chinese], [in Chinese]. Dyson spectral imaging system with large relative aperture and wide spectral region[J]. Optics and Precision Engineering, 2013, 21(10): 2535

    [6] GE Mingfeng, QI Hongxing, WANG Yuxi, ZHOU Panwei, HAN Guicheng. Spectral Calibration for the High Spectral Resolution Imager[J]. Opto-Electronic Engineering, 2015, 42(12): 14

    QI Xiang-dong, HAN Peng-peng, PAN Ming-zhong, CUI Ji-cheng. Spectral calibration of imaging spectrometer with convex grating[J]. Optics and Precision Engineering, 2011, 19(12): 2870