• Acta Optica Sinica
  • Vol. 41, Issue 9, 0912003 (2021)
Yiwei Hao1、2、3, Xinxin Kong1、2, Qisheng Cai1、2, Wenxi Zhang1、2、3、*, Zhou Wu1、2, Yu Dai1、2、3, and Yongbiao Wang1、2
Author Affiliations
  • 1Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
  • 2Key Laboratory of Computational Optical Imaging Technology, Chinese Academy of Sciences, Beijing 100094, China
  • 3School of Optoelectronics, University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.3788/AOS202141.0912003 Cite this Article Set citation alerts
    Yiwei Hao, Xinxin Kong, Qisheng Cai, Wenxi Zhang, Zhou Wu, Yu Dai, Yongbiao Wang. Analysis of Effect of Circulator Noise on Laser Interferometry System[J]. Acta Optica Sinica, 2021, 41(9): 0912003 Copy Citation Text show less
    Principle diagram of laser interferometer ring
    Fig. 1. Principle diagram of laser interferometer ring
    Internal structure of typical circulator
    Fig. 2. Internal structure of typical circulator
    Relationship between displacement error and direction of circulator and its local magnification
    Fig. 3. Relationship between displacement error and direction of circulator and its local magnification
    Point diffraction spatial light circulator
    Fig. 4. Point diffraction spatial light circulator
    Contrast test object of circulator displacement measurement
    Fig. 5. Contrast test object of circulator displacement measurement
    Displacement measurement results of two circulators. (a) 1st set of measurement; (b) 2nd set of measurement; (c) 3rd set of measurement; (d) local magnification of 3rd set of measurement
    Fig. 6. Displacement measurement results of two circulators. (a) 1st set of measurement; (b) 2nd set of measurement; (c) 3rd set of measurement; (d) local magnification of 3rd set of measurement
    Displacement error of two circulators at different moments. (a) 3.000-3.010 s; (b) 5.000-5.010 s; (c) 7.000-7.010 s
    Fig. 7. Displacement error of two circulators at different moments. (a) 3.000-3.010 s; (b) 5.000-5.010 s; (c) 7.000-7.010 s
    Displacement measurement data of two circulators in different target states. (a) State of rest; (b) state of motion
    Fig. 8. Displacement measurement data of two circulators in different target states. (a) State of rest; (b) state of motion
    CirculatorP1 /WPr /WUDmax /VG /(V·W-1)P3 /WD /dB
    11.40×10-21.00×10-48.30×10-41061.72×10-15129
    21.27×10-21.00×10-40.801066.56×10-963
    Table 1. Directionality calculation results of two circulators
    Yiwei Hao, Xinxin Kong, Qisheng Cai, Wenxi Zhang, Zhou Wu, Yu Dai, Yongbiao Wang. Analysis of Effect of Circulator Noise on Laser Interferometry System[J]. Acta Optica Sinica, 2021, 41(9): 0912003
    Download Citation