Chunmiao Xu, Wenlin Gong. Passive Ranging and Refocusing Method Based on Two-Frame Detection Signals[J]. Acta Optica Sinica, 2025, 45(7): 0712002

Search by keywords or author
- Acta Optica Sinica
- Vol. 45, Issue 7, 0712002 (2025)

Fig. 1. Diagram of traditional optical imaging for imaging same target at different detection distances

Fig. 2. Passive ranging and refocusing method based on two-frame detection signals. (a) Schematic of passive ranging based on two-frame detection signals; (b) architecture of passive ranging and refocusing based on two-frame detection signals

Fig. 3. Signal processing and distance solution of coarse ranging method based on two-frame detection signals and IQEF

Fig. 4. Image reconstruction results and edge images corresponding to the first frame detection signal. (a) Image recorded by detector when 253.0 mm; (b) CS reconstruction results based on PSF measurement matrix at different detection distances; (c) edge images corresponding to (b)

Fig. 5. Image reconstruction results and edge images corresponding to the second frame detection signal. (a) Image recorded by detector when detection distance is 254.0 mm; (b) CS reconstruction results based on PSF measurement matrix at different detection distances; (c) edge images corresponding to (b)

Fig. 6. Normalized IQEF curves obtained by two-frame detection signals

Fig. 7. Curves of IQEF in different PSF searching steps

Fig. 8. Curves of IQEF in different axial distance differences

Fig. 9. Validation of precision ranging algorithm based on orthogonal constraint. (a) Image reconstruction results without orthogonal constraint; (b) image reconstruction results with orthogonal constraint

Fig. 10. Tomographic image reconstruction results based on TVAL3+OC in different tomographic steps. (a) Reconstruction results corresponding to PSFs of 252.45, 252.8, and 253.15 mm with a tomographic step of ; (b) reconstruction results corresponding to PSFs of 252.62, 252.8, and 252.98 mm with a tomographic step of ; (c) reconstruction results corresponding to PSFs of 252.71, 252.8, and 252.89 mm with a tomographic step of ; (d) reconstruction results corresponding to PSFs of 252.755, 252.8, and 252.845 mm with a tomographic step of ; (e) reconstruction results corresponding to PSFs of 252.778, 252.8, and 252.822 mm with a tomographic step of
|
Table 1. TVAL3+OC algorithm scheme
|
Table 2. Distance decoupling based on MSE evaluation

Set citation alerts for the article
Please enter your email address