• Opto-Electronic Engineering
  • Vol. 30, Issue 3, 1 (2003)
[in Chinese]1, [in Chinese]2, [in Chinese]1, [in Chinese]2, [in Chinese]2, and [in Chinese]2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: Cite this Article
    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Property Study for Hartmann Sensor Used in Measuring Wave Aberration of Human Eye[J]. Opto-Electronic Engineering, 2003, 30(3): 1 Copy Citation Text show less
    References

    [2] Howland H C, Buettner J .Computing high order wave aberration coefficients from variations of best focus for small artificial pupils[J]. Vision Res. 1989, 29: 979-983.

    [3] Liang J, Williams D R .Supernormal vision and high-resolution retinal imaging through adaptive optics[J]. J.Opt. Soc. Am. 1997, A 14(11) : 2884-2892.

    [4] Artal P, Marcos S, et al .Odd aberrations and double-pass measurements of retinal image quality[J]. J.Opt. Soc. Am. 1997, A 12(2) : 195-201.

    [5] He J C, Marcos S .Measurement of the wave-front aberration of the eye by a fast psychophysical procedure[J]. J.Opt. Soc. Am. 1998, A 15: 2449-2455.

    [6] Prieto P M, Vargas-Martin F .Analysis of the performance of the Hartmann-Shack sensor in the human eye[J]. J.Opt. Soc. Am. 2000, A 17(8) : 1388-1398.

    [7] Southwell W H .Wave-front estimation from wave-front slope measurements[J]. J.Opt. Soc. Am. 1980,A 70(8) : 998-1006.

    [8] Sliney D, Wolbarsht M .Safety with Lasers and Other Optical Sources[M]. New York: Plenum, 1980.

    [9] Laksminarayanan V .Lie algebraic treatment of dioptric power and optical aberrations[J]. J.Opt. Soc. Am. 1998, A 15:2497-2503.

    CLP Journals

    [1] LIANG Chun, SHENG Jian-xin, TONG Gui, LI Bang-ming. A Self-reference Method for Measuring Hartmann-Shack Wavefront Sensor Parameter[J]. Acta Photonica Sinica, 2009, 38(4): 780

    [2] ZHANG Wei-guo, DONG Xiao-chun, DU Chun-lei. Zooming Method for Microlens Array Imaging Photolithography[J]. Opto-Electronic Engineering, 2010, 37(3): 39

    [3] Xu Ancheng, Chen Jiabi, Zhang Peiming. Error Analysis of Ocular Aberration Measurement Instrument Based on Hartmann-Shack Wavefront Sensor[J]. Laser & Optoelectronics Progress, 2010, 47(8): 82801

    [4] Xu Ancheng, Chen Jiabi, Zhang Peiming. Error Analysis of Ocular Aberration Measurement Instrument Based on Hartmann-Shack Wavefront Sensor[J]. Laser & Optoelectronics Progress, 2010, 47(8): 82801

    [5] Zhang Jinping, Zhang Zhongyu, Zhang Xuejun, Li Ruigang. Algorithm for Extending Dynamic Range of Shack-Hartmann Wavefront Sensor[J]. Acta Optica Sinica, 2011, 31(8): 812006

    [6] Xu Zhengkui, Li Xiaobin, Le Lizhu, Yu Zhenlong, He Jun, Wang Chunxing. Design of microlens array of infrared two-band laminated structure detector[J]. Infrared and Laser Engineering, 2019, 48(8): 803003

    [7] WANG Xiao, SUN Tian-yu, FANG Dan, LIU Jun-cheng, TANG Ji-long, FANG Xuan, WANG Deng-kui, ZHANG Bao-shun, WEI Zhi-peng. Process Research of Wedge Mode Size Converter[J]. Acta Photonica Sinica, 2019, 48(6): 623001

    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Property Study for Hartmann Sensor Used in Measuring Wave Aberration of Human Eye[J]. Opto-Electronic Engineering, 2003, 30(3): 1
    Download Citation